Thanks for your prompt response (and to Rob for his response). You are right, my mistake, it is a warning. Besides its nature, it prevents the gnu-radio flowgraph from working at all, and prevents uhd_usrp_probe from displaying the correct block name.
Setting up the environment variable worked just fine, but I'm wondering how I should include two OOT blocks if I've to set the env variable to one path? Thank you. Lautaro. El vie, 11 feb 2022 a la(s) 11:43, Brian Padalino ([email protected]) escribió: > On Fri, Feb 11, 2022 at 8:16 AM Lautaro Lorenzen < > [email protected]> wrote: > >> Hi everyone, >> >> I'm trying to follow the RFNoC 4 workshop and I've come up with an error >> when I'm trying to load the image to an ettus 312. I think my environment >> is set up correctly but any help would be appreciated. >> It is worth noting that I'm trying to use RFNoC with gnu-radio. >> I've also seen an email from 2020 but I'm not sure how I could put my >> custom block "in-tree" to solve this issue. >> >> The error: >> [WARNING] [RFNOC::BLOCK_FACTORY] Could not find block with Noc-ID >> 0x501de012, 0xffff >> > > This is a warning, not an error. > > To alleviate this, you need to set the UHD_MODULE_PATH environment > variable to the path where your out-of-tree library for this block is > located. > > Brian >
_______________________________________________ USRP-users mailing list -- [email protected] To unsubscribe send an email to [email protected]