Thanks. This worked kind regards JP
-----Original Message----- From: Marcus D. Leech <patchvonbr...@gmail.com> Sent: Thursday, 3 March 2022 07:57 To: usrp-users@lists.ettus.com Subject: [USRP-users] Re: single flow utilising multiple receivers with high sample rate WARNING: This message has originated from an untrusted source. Be mindful of attachments and embedded links. On 2022-03-02 16:23, Jonathan Pratt wrote: > Well, yes I do want to do that. > > It's a test of data transfer capabilities of the PC in preparation for use > with an X410 in the future (but I don't have an X410 yet). > > The other reason for over sampling the band is that in detecting a pulse of > RF signal, the precise start time is very important in our application so > that the higher sample rate affords better resolution in that regard. > The X310 has two 10GbE interfaces, is there not an approved way of using them > in this manner? What if I had 2 x TwinRx and wanted to get 100MSPS from all > four of them? > > kind regards > JP > > You just need to use the "second_addr" syntax, as I linked earlier in this thread. The "addrN=" syntax you're using is for multiple USRPs. You'll also need the correct FPGA image to support 10GiGe on both ports, but I think you'd already said you'd done that. _______________________________________________ USRP-users mailing list -- usrp-users@lists.ettus.com To unsubscribe send an email to usrp-users-le...@lists.ettus.com _______________________________________________ USRP-users mailing list -- usrp-users@lists.ettus.com To unsubscribe send an email to usrp-users-le...@lists.ettus.com