Hi,

I am trying to get a working multi-usrp setup with both X300 and N300.

I currently have a signal generator generating a 10 MHz clock and a 1PPS signal.
Those are connected to a splitter (each), and then connected to both X300s REF 
IN and 1PPS IN.
This setup works, and with srsRAN I can use two X300's to get an LTE 2x2 MIMO 
setup with the throughput I get with one X300.

If I connect the same signal to the N300, the N300's PLL fails to get a lock.

Does anyone have any idea what goes wrong there? We're getting a WR switch 
somewhere in the future, but I would like to be able to test
with the N300s before it arrives.

Regards,