At 08:09 PM 6/30/01 -0500, Harvey Barlow wrote:
>With the door open, I noticed a couple of plugs on the outside edges of the
>face of the refrig, apparently concealing screws placed through the face of
>the refrig into the vertical framing on each side of the door. Is that the
>ones you removed? From previous list discussions I remember reading I'm
>afraid there are also lag bolts through the floor and base of the refrig.
>Does anyone know? I'm worried about how to get to them.
It's been a couple of years since I replaced a refrigerator in an
'85- so this is from memory-
The only screws into the floor will be in the rear of the 'frige-
the only non-standard thing (other than the screws through the face frame-
behind the plugs) that I have ever seen is screws through the side- if you
have a cupboard beside the rfrigerator, look in there for screw heads- also
sometimes through a partition type wall.
Keep in mind that a new replacement refrigerator will mount
differently- new ones use two screws through the top- two through the
bottom, two in back, and no holes through the face frame.
________
Chris Bryant
To unsubscribe or to change to a daily Digest, please go to
http://www.airstream.net/vaclist/listoffice.html
If replying back to this message, please delete all the unnecessary original
text from your reply.