Well at a guess I would re-apply the Emulex driver to the HBAs. Go into device manager, right click on the HBA, and ask to Update Driver. If you tell it to look in /windows/system32 for the driver it may find it, without you needing the CD. Excuse me being a bit vague, I have not tried it. You can also check if you look at the Driver Details tab just which files & driver it is using, I guess you will see it using hbaapi.dll. At least you will be able to see if you succeed in changing it.
William D L Brown [EMAIL PROTECTED] Sent by: [EMAIL PROTECTED] 18-Jan-2006 15:56 To veritas-bu@mailman.eng.auburn.edu cc Subject [Veritas-bu] Blocksize problem after upgrading EMC powerpath ( UPDATE) Hello All I have now by trial and error figured out that it wasn't EMC powerpath, but Windows 2003 SP1 which puts a microsoft hbaapi.dll into system32 in place of the emulex one. At the moment there's hbaapi.dll (from microsoft, 64Kb limit) and emulexhbaapi.dll (at least 256kb) in system32 on the servers in question. Now I just need to figure how to get the tape drivers to use the emulexhbaapi.dll, any ideas ? Regards Michael -- Cybercity Webhosting (http://www.cybercity.dk) _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu