The make and model are in the subject.

Quantum is specifically asking us to change to application based cleaning from 
robot based due to ongoing issue.   Also in reviewing NetBackup documentation 
it seems to suggest that robot based cleaning should not be used.

________________________________
From: [email protected] 
[mailto:[email protected]] On Behalf Of Len Boyle
Sent: Thursday, February 02, 2012 6:09 PM
To: Lightner, Jeff; [email protected]
Subject: Re: [Veritas-bu] Cleaning tape setup Quantum i6000 Library

What is the make and model of you tape library. A number of them require that 
the library do the tape drive cleaning.

From: [email protected] 
[mailto:[email protected]] On Behalf Of Lightner, Jeff
Sent: Thursday, February 02, 2012 4:17 PM
To: [email protected]
Subject: [Veritas-bu] Cleaning tape setup Quantum i6000 Library

To set NetBackup cleaning as opposed to robot cleaning itself I gather we need 
to setup barcode rules as discussed in the following thread:
http://www.symantec.com/connect/forums/cleaning-tape-cln

I've done that but am curious if they are correct about having to set HC2_CLN 
for HCART2 and HC_CLN for HCART?   We have a mix of LTO3 (which we have as 
HCART) and LTO5 (which we have as HCART2) but the cleaning tapes are 
"Universal" so would work in either drive type.  Do I really have to try to 
setup both HC_CLN and HC2_CLN?  It seemed to me that the HC_CLN and HC2_CLN 
were just to allow you to have 2 different kinds of cleaning tapes.

Additionally - I've disabled the robot's automatic cleaning and moved the 
cleaning tapes from the special cleaning slots to the general slots.   Other 
than that and setting the barcode rules is there anything I need to do to 
enable NBU cleaning?

The drive cleaning frequency is set to 0 hours.  Is it correct to think this is 
appropriate because I want the cleaning to be based on "tape alerts" rather 
than frequency based on the recommendation I saw in the NBU help?


Jeffrey C. Lightner
Sr. UNIX Administrator

DS Waters of America, Inc.
5660 New Northside Drive NW
Suite 250
Atlanta, GA  30328

P: 678-486-3516
C: 678-772-0018
F: 770-937-7360
E: [email protected]<mailto:[email protected]>










Athena(r), Created for the Cause(tm)

Making a Difference in the Fight Against Breast Cancer



---------------------------------
CONFIDENTIALITY NOTICE: This e-mail may contain privileged or confidential 
information and is for the sole use of the intended recipient(s). If you are 
not the intended recipient, any disclosure, copying, distribution, or use of 
the contents of this information is prohibited and may be unlawful. If you have 
received this electronic transmission in error, please reply immediately to the 
sender that you have received the message in error, and delete it. Thank you.
----------------------------------


_______________________________________________
Veritas-bu maillist  -  [email protected]
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

Reply via email to