Anurag,

This is not correct.

Several DD models have been qualified by Symantec and EMC for DD Boost over
FC on NBU 7.6 and DD OS 5.3+/BOOST plug-in 2.6+

You may want check NBU HCL and my.datadomain.com if you have missed the
announcement from EMC.

Best regards, Mikhail
On 01/02/2014 6:39 pm, "Anurag Sharma" <sharma.anu...@hotmail.com> wrote:

> Sunit
>
> DDBOOST on FC not possible.
>
> Do FC if you want VTL deployments.
>
> DDBOOST works at high speed on 10g network.
>
> So it depends what you have if you can have 10g connectivity between media
> servers and DD then go for DDBOOST
>
> else go fibre with VTL implementation
>
> Also you can not use one DD device as VTL and DDBOOST at the same time.
>
> Anurag
>
> ------------------------------
> Date: Mon, 27 Jan 2014 23:58:33 +1100
> From: mikhail.niki...@gmail.com
> To: sunilgulati1...@gmail.com
> CC: VERITAS-BU@mailman.eng.auburn.edu
> Subject: Re: [Veritas-bu] Netbackup With Data Domain,
>
> Hi Sunil,
>
> I believe you can use DD Boost over FC between media server and DD. With
> NetWorker you can use ClientDirect with FC, too if memory serves me well.
> However, DDs can't replicate over FC atm, you have to use 1 or 10 gig
> links to replicate data.
>
> Of course you need DD OS 5.4+, DD Boost plug-in 2.6+ and NBU 7.6. Don't
> forget to check your FC infrastructure with EMC for DD Boost over FC
> compatibility. EMC pre-sales should pass your configuration through a
> qualification process, in theory.
>
> Best regards, Mikhail
>  On 27/01/2014 8:46 pm, "Sunil Gulati" <sunilgulati1...@gmail.com> wrote:
>
> Hello,
>
> Can we use DDboost feature over FC ? Like I have production and a DR site
> in my environment. I have data domain & netbackup media servers at both
> location. I have kept tape library at my primary site for tape outs.
>
> I want to use SLP which will run 4 backup jobs  (Backup, Replication,
> Import & duplication) means I'll be replicating my backup images from
> production site to DR site using DDboost.
>
> I want to know if I can use the same over FC ?
>
> Thanks
>
> Sunil
>
>
>
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>
>
> _______________________________________________ Veritas-bu maillist -
> Veritas-bu@mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>
_______________________________________________
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

Reply via email to