On Thu, May 18, 2023 at 03:42:19PM -0400, Michael S. Tsirkin wrote: > > > Does this sound like a reasonable > > > compromize to you? > > > > Splitting proposed one command to two commands, > > 1. one for accessing legacy common config > > 2. second for accessing legacy device specific config > > > > seems fine to me as below. > > > > So we will have total 5 commands (instead of 3). > > > > 1. legacy common config read > > 2. legacy common config write > > > > 3. legacy device config read > > 4. legacy device config write > > 5. query device notification area > > > > #1 and #3 same cmd signature but different opcode. > > #2 and #4 same cmd signature but different opcode. > > > > Sounds reasonable. Jason? > > notification thing needs more thought I feel though. > It feels weirdly bolted on, but I can't put my finger > on what's wrong exactly yet. Will think it over.
So with a fresh mind, at least three things: 1. given driver attaches to the PF, it should be possible to forward notifications there, as opposed to individual VFs. NumVFs is 16 bit so it will fit in a 32 bit write together with VQ index. 2. It should be possible to send notifications through an admin command too, otherwise admin commands are an incomplete set of functionality. 3. I feel using a capability to describe legacy notification area would be better just because we already have a structure for this. make it an express capability if you like. -- MST --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]