Sock will be NULL if we pass -1 to vhost_net_set_backend(), but when
we meet errors during ubuf allocation, the code does not check for
NULL before calling sockfd_put(), this will lead NULL
dereferencing. Fixing by checking sock pointer before.

Fixes: bab632d69ee4 ("vhost: vhost TX zero-copy support")
Reported-by: Dan Carpenter <[email protected]>
Signed-off-by: Jason Wang <[email protected]>
---
 drivers/vhost/net.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/vhost/net.c b/drivers/vhost/net.c
index 986058a..b97a994 100644
--- a/drivers/vhost/net.c
+++ b/drivers/vhost/net.c
@@ -1208,7 +1208,8 @@ static long vhost_net_set_backend(struct vhost_net *n, 
unsigned index, int fd)
        if (ubufs)
                vhost_net_ubuf_put_wait_and_free(ubufs);
 err_ubufs:
-       sockfd_put(sock);
+       if (sock)
+               sockfd_put(sock);
 err_vq:
        mutex_unlock(&vq->mutex);
 err:
-- 
2.7.4

_______________________________________________
Virtualization mailing list
[email protected]
https://lists.linuxfoundation.org/mailman/listinfo/virtualization