On Saturday 14 January 2006 23:50, you wrote:
>
> Some client do need a dataconnection through the * box. Eg. When they use
> billing software. They need to establish a data connection to their central
> server.

Ok, but what kind of connection is that? Analog, sync PPP, v.110, v.120, 
other?

> Ist not good enough for them to have a network connection. 
> Or could i terminate the dataconnection to * and have * start another pppd
> connection to the remote server and bridge those 2 channels ?!?

Mmmh... if it is sync PPP, it would be better to enable the HDLC framer on 
both boards and pass frames instead of transparent data, however this is not 
supported yet.

Bye,

-- 
  Daniele Orlandi
_______________________________________________
Visdn-hackers mailing list
[email protected]
https://mailman.uli.it/mailman/listinfo/visdn-hackers