On 1/24/06, EXT / DUBOIS Laurent <[EMAIL PROTECTED]> wrote: > But my question still remains the same : is it possible to have the 3270 data > stream accessible from the 1st level system (as if I did a view in the spool > for example or in a view like the secondary console). ??
The primary console is kind of special in 3215 mode since CP simulates the real device. For the rest of them, you need to have a terminal dialed to the guest or your I/O to the virtual device will fail. For 2nd level VM systems you define a GRAF and DIAL to it to get a 'local 3270' on the 2nd level system. And then there's applications like VSCS or TCP/IP that simulate a device through CP's logical device support. Rob -- Rob van der Heij rvdheij @ gmail.com Velocity Software, Inc
