No, it's really just 1-9 clicks, or 10 clicks for 0. I've got a rotary dial on the desk next to me.

On 1/21/21 6:42 PM, Pete Mundy wrote:
So close! But on the PoTS equipment I'm familiar with (others can chime in and 
correct me if I'm wrong on a larger scale) the numbers are reversed

(well for all except 5 :)

Basically it counts down from 10. 1 pulse is digit '9', 4 pulses is digit '6', 
10 pulses is digit '0'.

So do dial 911 you need:

        1 brief loop interruption
        pause
        9 brief loop interruptions
        pause
        9 brief loop interruptions

<wield flame suit>

Pete


On 22/01/2021, at 12:07 PM, Mike Johnston <mjohns...@wiktel.com> wrote:
<snip>
One interrupt represents the digit "1" being dialed.  Two rapid interrupts represents the 
digit "2", and so on.  You need to have at least a brief timeout
<snip>
_______________________________________________
VoiceOps mailing list
VoiceOps@voiceops.org
https://puck.nether.net/mailman/listinfo/voiceops


_______________________________________________
VoiceOps mailing list
VoiceOps@voiceops.org
https://puck.nether.net/mailman/listinfo/voiceops

Reply via email to