The HT8XX series ATA FXS Ports should have an option for “Enable High Ring 
Power” you could try enabling.

~Matthew


> On Mar 14, 2022, at 3:50 PM, Mike Hammett <[email protected]> wrote:
> 
> A customer of mine has a Mitel 3300 PBX. We deliver to them analog lines.
> 
> 
> Everything worked fine for months, if not years. Then one day they say they 
> can't receive inbound calls. They can still place outbound calls.
> 
> They're on a Grandstream HT818 ATA. I move some lines to the Zhone ONT that's 
> on-site. No improvement.
> 
> I plug in a normal analog handset from Walmart or Menards. They all ring and 
> answer just fine.
> 
> I plugged in a patch cable from their Mitel ONS2 to the analog trunk 5 and 
> they set up an extension on that ONS2 so that a call to it would trigger an 
> inbound call on their analog line. Apparently that worked.
> 
> The Mitel support agent is saying that we're not sending them between 24v - 
> 48v.
> 
> All cables are 6' at most.
> 
> A) I don't see anywhere to configure voltage on either platform.
> B) I don't know how it could work and then just stop, other than equipment 
> failure.
> C) I don't know how it would work just fine on a COTS phone, but not their 
> Mitel.
> D) I don't know how the same problem could also afflict another ATA (build 
> into the ONT).
> 
> 
> Any tips?
> 
> 
> 
> 
> -----
> Mike Hammett
> Intelligent Computing Solutions
> http://www.ics-il.com <http://www.ics-il.com/>
> 
> 
> 
> Midwest Internet Exchange
> http://www.midwest-ix.com <http://www.midwest-ix.com/>
> 
> 
> 
> _______________________________________________
> VoiceOps mailing list
> [email protected] <mailto:[email protected]>
> https://puck.nether.net/mailman/listinfo/voiceops 
> <https://puck.nether.net/mailman/listinfo/voiceops>
_______________________________________________
VoiceOps mailing list
[email protected]
https://puck.nether.net/mailman/listinfo/voiceops

Reply via email to