Bob Fickle wrote:

> I have " ...attempted to estimate how fast the filament will heat up".
>  From the description on JLN's web page, I estimate the filament has a
> mass of about 1.2g, and would require about 200 Joules to heat from an
> average temperature of  ~700K to the "operating" temperature of 2000K.
> The input during the short pulses is much less than this.  I posted this
> calculation to JLN about 10 days back, but have no reply as yet.

What assumptions did you make to allow the calculation of input
power during the pulse? Are the numbers that JLN reports actually
average voltage and current as the labels, now changed, on his
web site once indicated? If they are, the input power calculations are low
by a factor of 1/(duty cycle) or about 20 and the system actually is close
to
unity.

George Holz
Varitronics Systems


Reply via email to