Water and Ammonia should be fairly close in flow rate. At 0.01 moles/sec (0.18 grams/sec)
with 1.60 " Hg  (94 F) high side and  0.80 "  Hg low (condensing side at 73  F) gives the orifice
diameter as 0.048647 inches.
 
 
http://www.lenoxlaser.com/calculator/orifice.asp
 
Is drawing on technology that Hero came up with almost 2,000 years ago considered
" Back Engineering"?
 