> From: "David Roberson" <[email protected]>
> Sent: Wednesday, June 5, 2013 3:14:05 PM
> Alan,
> 
> I am interested in your model and have a question. For some reason I
> did not locate the case where thermal run away occurred. I suspect
> that I missed that in the large volume of material. Could you direct
> me to that location?

I don't have a CONTROL MODEL yet .. I just inject a waveform and tweak it until 
it a) matches the observed output, and b) has a temperature profile at the 
center which MIGHT be used by a model. 

In my environment I would simulate run-away by injecting a constant amount of 
heat quickly enough that it can't be dissipated.

> You mention that I may be assuming a linear internal power generation
> process, but that is not what I am doing with my model. I assume a
> polynomial series for this purpose. Any mathematical relationship
> can be tested with my simulation and I have tested the old tried and
> true exponential curve as well. Each one has its own quirks and can
> lead to thermal run away when the COP get large.

I'll take out the statement that it's linear. If you want to give me a short 
formal statement I can put it in a box quote.