Hi,

It seems like VOTCA has an additional factor 10 when converting between 
Angstroms and nm:
the COM coors calculated from lammps dump in VMD are as they are supposed 
to be in Angstroms, but the output from csg_map is 10 times larger. In the 
example above the coordinates of B1 bead should be 1.6348 -13.9948  3.7050 
in Angstroms or 0.16348 -1.399 0.37 in nm, but they are multiplied by 10, 
 i.e. the output units are 10^-11, not 10^-9.
Of course I can scale the output manually, but I am not sure if the same 
routine is used in other scripts like csg_stat or csg_boltzmann. Can you 
check if the same scaling problem exists in the internal routines of other 
scripts?
Best,