On Sun, Feb 22, 2009 at 07:58:54PM -0800, Alex Mandel wrote: > sudo smartctl -H /dev/sda
Gives me: === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED Please note the following marginal Attributes: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 190 Airflow_Temperature_Cel 0x0022 058 041 045 Old_age Always In_the_past 42 (Lifetime Min/Max 38/49) 240 Head_Flying_Hours 0x0000 000 000 000 Old_age Offline FAILING_NOW 179710021603702 241 Unknown_Attribute 0x0000 000 000 000 Old_age Offline FAILING_NOW 2384165937 242 Unknown_Attribute 0x0000 000 000 000 Old_age Offline FAILING_NOW 30165814 So I'm getting "PASSED", plus "FAILING_NOW"...? > Gives you the basic yes/no > > sudo smartctl -a /dev/sda Attached as an attachment... Looks like a bunch of "Pre-fail" and "Old-age" reports...? -bill!
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.2 Device Model: ST9120823ASG Serial Number: 5NJ11W2Z Firmware Version: 3.ADD User Capacity: 120,034,123,776 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Feb 24 14:45:52 2009 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 426) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 111) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 099 098 085 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 485 5 Reallocated_Sector_Ct 0x0033 098 098 036 Pre-fail Always - 111 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 17241171744 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 4449 10 Spin_Retry_Count 0x0013 100 100 034 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 495 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 245 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 058 041 045 Old_age Always In_the_past 42 (Lifetime Min/Max 38/49) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 1 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 400 193 Load_Cycle_Count 0x0022 001 001 000 Old_age Always - 464085 194 Temperature_Celsius 0x001a 042 059 000 Old_age Always - 42 (0 17 0 0) 195 Hardware_ECC_Recovered 0x0012 065 060 000 Old_age Always - 243810737 197 Current_Pending_Sector 0x0010 100 100 000 Old_age Offline - 9 198 Offline_Uncorrectable 0x003e 100 100 000 Old_age Always - 9 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 0 200 Multi_Zone_Error_Rate 0x0032 100 253 000 Old_age Always - 0 202 TA_Increase_Count 0x0000 100 253 000 Old_age Offline - 0 240 Head_Flying_Hours 0x0000 000 000 000 Old_age Offline FAILING_NOW 247518965272950 241 Unknown_Attribute 0x0000 000 000 000 Old_age Offline FAILING_NOW 2384167521 242 Unknown_Attribute 0x0000 000 000 000 Old_age Offline FAILING_NOW 30185294 254 Unknown_Attribute 0x0000 001 001 000 Old_age Offline - 167 SMART Error Log Version: 1 ATA Error Count: 245 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 245 occurred at disk power-on lifetime: 4448 hours (185 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fa e5 30 e9 Error: UNC at LBA = 0x0930e5fa = 154199546 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f6 e5 30 e9 00 08:29:12.864 READ DMA 27 00 00 00 00 00 e0 00 08:29:18.513 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 00 08:29:18.513 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 08:29:18.512 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 08:29:18.512 READ NATIVE MAX ADDRESS EXT Error 244 occurred at disk power-on lifetime: 4448 hours (185 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fa e5 30 e9 Error: UNC at LBA = 0x0930e5fa = 154199546 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f6 e5 30 e9 00 08:29:12.864 READ DMA 27 00 00 00 00 00 e0 00 08:29:12.863 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 00 08:29:12.863 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 08:29:12.862 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 08:29:09.970 READ NATIVE MAX ADDRESS EXT Error 243 occurred at disk power-on lifetime: 4448 hours (185 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fa e5 30 e9 Error: UNC at LBA = 0x0930e5fa = 154199546 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f6 e5 30 e9 00 08:29:12.864 READ DMA 27 00 00 00 00 00 e0 00 08:29:12.863 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 00 08:29:12.863 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 08:29:12.862 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 08:29:09.970 READ NATIVE MAX ADDRESS EXT Error 242 occurred at disk power-on lifetime: 4448 hours (185 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fa e5 30 e9 Error: UNC at LBA = 0x0930e5fa = 154199546 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f6 e5 30 e9 00 08:29:07.089 READ DMA 27 00 00 00 00 00 e0 00 08:29:03.883 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 00 08:29:03.883 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 08:29:03.882 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 08:29:09.970 READ NATIVE MAX ADDRESS EXT Error 241 occurred at disk power-on lifetime: 4448 hours (185 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fa e5 30 e9 Error: UNC at LBA = 0x0930e5fa = 154199546 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f6 e5 30 e9 00 08:29:07.089 READ DMA 27 00 00 00 00 00 e0 00 08:29:03.883 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 00 08:29:03.883 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 08:29:03.882 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 08:29:03.882 READ NATIVE MAX ADDRESS EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1 - # 2 Short offline Completed without error 00% 0 - # 3 Short offline Interrupted (host reset) 90% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
_______________________________________________ vox-tech mailing list [email protected] http://lists.lugod.org/mailman/listinfo/vox-tech