Hi all.

This is a revised version of my previous patch to fix negative
temperature readings of the LM77 in kernel 2.6.x.

Bye, Mike
--- Begin Message ---
Content-Disposition: inline; filename=hwmon-lm77-negative-temp-fix.patch

Fix negative temperature readings in lm77 driver.

Signed-off-by: Jean Delvare <[EMAIL PROTECTED]>
Acked-by: Michael Renzmann <[EMAIL PROTECTED]>
---
 drivers/hwmon/lm77.c |    8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

--- linux-2.6.15-rc6.orig/drivers/hwmon/lm77.c  2005-12-19 20:15:58.000000000 
+0100
+++ linux-2.6.15-rc6/drivers/hwmon/lm77.c       2005-12-20 19:44:11.000000000 
+0100
@@ -87,15 +87,15 @@
 
 /* In the temperature registers, the low 3 bits are not part of the
    temperature values; they are the status bits. */
-static inline u16 LM77_TEMP_TO_REG(int temp)
+static inline s16 LM77_TEMP_TO_REG(int temp)
 {
        int ntemp = SENSORS_LIMIT(temp, LM77_TEMP_MIN, LM77_TEMP_MAX);
-       return (u16)((ntemp / 500) * 8);
+       return (ntemp / 500) * 8;
 }
 
-static inline int LM77_TEMP_FROM_REG(u16 reg)
+static inline int LM77_TEMP_FROM_REG(s16 reg)
 {
-       return ((int)reg / 8) * 500;
+       return (reg / 8) * 500;
 }
 
 /* sysfs stuff */

-- 
Jean Delvare