Thanks Matthew.
Will put you into the review list for both vpp and dpdk patch.
And will refer the bug ID you created in the dpdk patch.
Thanks.
From: Matthew Smith <mgsm...@netgate.com>
Sent: 2020年3月18日 23:45
To: Lijian Zhang <lijian.zh...@arm.com>
Cc: vpp-dev <vpp-dev@lists.fd.io>; nd <n...@arm.com>; Honnappa Nagarahalli 
<honnappa.nagaraha...@arm.com>; Juraj Linkeš <juraj.lin...@pantheon.tech>; 
Govindarajan Mohandoss <govindarajan.mohand...@arm.com>; Jieqiang Wang 
<jieqiang.w...@arm.com>
Subject: Re: [vpp-dev] False link down issue with X520-2 NIC on CSIT Taishan 
server

Hi Lijian,

Yes, that seems like a good idea to me.

There is a VPP patch that I added for DPDK 19.08 to deal with the same issue at 
build/external/patches/dpdk_19.08/0001-ixgbe-fix-link-state-timing-issue-on-fiber-ports.patch.
 It looks like my patch may not apply cleanly to DPDK 20.02 because they 
changed how the task to update link status is managed (rte_eal_alarm -> 
thread). When you submit your patch in gerrit, you are welcome to add me as a 
reviewer.

I reported a bug to DPDK when I saw this issue - 
https://bugs.dpdk.org/show_bug.cgi?id=388. If you need a "Fixes:" tag for your 
patch when you submit it to upstream DPDK, you could reference that bug ID.

Thanks,
-Matt


On Wed, Mar 18, 2020 at 9:12 AM Lijian Zhang 
<lijian.zh...@arm.com<mailto:lijian.zh...@arm.com>> wrote:
Hi Maintainers,

Currently CSIT performance testing failed on Taishan servers due to interface 
link down issue.

This issue is observed with X520-2 NICs on FD.io lab Taishan server. After VPP 
booting up and bringing up  the interfaces with command ‘set interface state 
<interface> up’, it still shows link down status from the command ‘show 
hardware-interfaces’. However, the hardware link status is actually up. 
dpdk_process() cannot get the hardware link status correctly via 
rte_eth_link_get_nowait().

In ixgbe_dev_link_update_share(), if the media type is fiber and the link is 
down, a flag (IXGBE_FLAG_NEED_LINK_CONFIG) is set. A callback to 
ixgbe_dev_setup_link_alarm_handler() is scheduled trying to set up the link and 
clear the flag afterwards.

If the device is started or stopped before the flag is cleared, the scheduled 
callback is canceled. This causes the flag to remain set and subsequent calls 
to ixgbe_dev_link_update_share() return without trying to retrieve the link 
state because the flag is set.
   4242     if (intr->flags & IXGBE_FLAG_NEED_LINK_CONFIG)
   4243         return rte_eth_linkstatus_set(dev, &link);

When the callback is canceled by either interface start or stop operations, in 
ixgbe_dev_cancel_link_thread(), after cancelling the callback/thread, unset the 
flag on the device to avoid this condition.

The code change to dpdk-20.02 to fix this issue is as below.
Can I put a patch to vpp patch directory (build/external/patches/dpdk_20.02/) 
to fix the issue temporarily, and meanwhile we will upstream a corresponding 
fixing patch in DPDK project?

diff --git a/drivers/net/ixgbe/ixgbe_ethdev.c b/drivers/net/ixgbe/ixgbe_ethdev.c
index 23b3f5b0c..aa882cb8b 100644
--- a/drivers/net/ixgbe/ixgbe_ethdev.c
+++ b/drivers/net/ixgbe/ixgbe_ethdev.c
@@ -4147,11 +4147,14 @@ static void
ixgbe_dev_cancel_link_thread(struct rte_eth_dev *dev)
{
        struct ixgbe_adapter *ad = dev->data->dev_private;
+       struct ixgbe_interrupt *intr =
+               IXGBE_DEV_PRIVATE_TO_INTR(dev->data->dev_private);
        void *retval;

        if (rte_atomic32_read(&ad->link_thread_running)) {
                pthread_cancel(ad->link_thread_tid);
                pthread_join(ad->link_thread_tid, &retval);
+               intr->flags &= ~IXGBE_FLAG_NEED_LINK_CONFIG;
                rte_atomic32_clear(&ad->link_thread_running);
        }
}
@@ -4262,8 +4265,8 @@ ixgbe_dev_link_update_share(struct rte_eth_dev *dev,
        if (link_up == 0) {
                if (ixgbe_get_media_type(hw) == ixgbe_media_type_fiber) {
-                       intr->flags |= IXGBE_FLAG_NEED_LINK_CONFIG;
                        if 
(rte_atomic32_test_and_set(&ad->link_thread_running)) {
+                               intr->flags |= IXGBE_FLAG_NEED_LINK_CONFIG;
                                if (rte_ctrl_thread_create(&ad->link_thread_tid,
                                        "ixgbe-link-handler",
                                        NULL,
Thanks.


-=-=-=-=-=-=-=-=-=-=-=-
Links: You receive all messages sent to this group.

View/Reply Online (#15813): https://lists.fd.io/g/vpp-dev/message/15813
Mute This Topic: https://lists.fd.io/mt/72049580/21656
Group Owner: vpp-dev+ow...@lists.fd.io
Unsubscribe: https://lists.fd.io/g/vpp-dev/unsub  [arch...@mail-archive.com]
-=-=-=-=-=-=-=-=-=-=-=-