18.01.2012 17:16, Taras пишет: > Hi, all! > > In our webui we run w3af_console with subprocess.Popen(). > There is frequent task to stop current scan and save at least partly > results of it. We use HTML output plugin for it which buffers results to > make nice HTML at the end. The problem is how to correctly stop such > scan. Currently we send KILL signal to this process but we lose report > in this case :( We also tried to send SIGINT but it no always works! > Some time report is completed but sometimes is not. Especially when w3af > run more then one mode, e.g. discovery then audit. So what we can do in > this case? Implement more usable signal handling in w3af. It was also the question :)
> Currently only SIGINT is catched because of catching Ctrl-C in w3af_console -- Taras http://oxdef.info ------------------------------------------------------------------------------ Keep Your Developer Skills Current with LearnDevNow! The most comprehensive online learning library for Microsoft developers is just $99.99! Visual Studio, SharePoint, SQL - plus HTML5, CSS3, MVC3, Metro Style Apps, more. Free future releases when you subscribe now! http://p.sf.net/sfu/learndevnow-d2d _______________________________________________ W3af-develop mailing list W3af-develop@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/w3af-develop