Monitor runs on port 56789 by default. Try edit/add
WOPort=<mymonitorport> in its Properties file inside the monitor.woa
itself.
The system property WOPort determines the port usually of a WO app. It
can be set in Properties (common during development), assigned
automatically by Monitor, IIRC configured specifically in Monitor
(check Monitor instance screen), or as a launch argument.
On Apr 17, 2008, at 11:35 AM, Anthony B Arthur wrote:
Can anyone tell me how to specify the port that monitor runs on? I
have searched the dev list, but not finding it. I suspect I can
specify a port for any WO app the same way. I need to do both.
Thanks,
--Brian