On Aug 28, 2008, at 3:43 AM, David Avendasora wrote:
Then it is likely the browser timing out instead of the user clicking something. EIther way the pipe between the browser and the server has gone down.
Or it could be the WO HTTP adaptor timing out when it doesn't receive a response from the WO app instance within the "receive timeout" period (30 seconds, by default). The HTTP adaptor will return a "No instance available" response when this occurs. The "receive timeout" can be increased in the "Load Balancing and Adaptor Settings" for the app in JavaMonitor.
Aloha, Art
smime.p7s
Description: S/MIME cryptographic signature
_______________________________________________ Do not post admin requests to the list. They will be ignored. Webobjects-dev mailing list ([email protected]) Help/Unsubscribe/Update your Subscription: http://lists.apple.com/mailman/options/webobjects-dev/archive%40mail-archive.com This email sent to [EMAIL PROTECTED]