This test fails at the submit with a javascript error. 
application/x-javascript     - just not sure how to address it.  I have 
tried with/ without javascript enabled.


The xmltest.

  <target name="wt.testInWork">
    <webtest name="ijenieLandingPage.xml">
      <config host="ijenie.ao.dcn/jenie/iwps/myportal" port="443" 
protocol="https" showhtmlparseroutput="true" />
      <steps>
                <invoke url="https://ijenie.ao.dcn/jenie/iwps/myportal"; 
description="get Login Page" />
                <verifyTitle text="JENIE Log-in" />
                <selectForm description="pkmslogin" name="form" />
                <setInputField description="user" name="usernameEntered" 
value="James Saxton" />
                <setInputField description="pw" name="password" 
value="Watch413" />
        <!-- enableJavaScript enable="false" -->
                <clickButton name="SUBMIT2" />
        <!-- /enableJavaScript -->
       </steps>
    </webtest>
  </target>
</project>


The result:



wt.webtestMonitor:
     [echo] /opt/canoo/tools/WebTestMonitor.groovy

wt.defineMacros:
     [echo] No macro to define

wt.generateDtd:
[groovyScript] Scanning for entities...
[groovyScript] 0 entities found
[groovyScript] Already uptodate: 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/dtd/Project.dtd

wt.generateDefinitions:
[groovyScript] Definitions dir not found: 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/definitions. Ignoring.

wt.createReportsFolder:

wt.deleteReports:

wt.parallel.init:

wt.before.testInWork:

wt.testInWork:
  [webtest]  INFO (com.canoo.webtest.ant.WebtestTask) - Starting webtest 
"ijenieLandingPage.xml" 
(/opt/canoo/myWebTestProject/tests/JeniePortal/tests/ijenieLandingPage.xml:7: 
)
  [webtest]  INFO (com.canoo.webtest.ant.WebtestTask) - Canoo Webtest: 
R_1758.
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Using 
haltonerror from project property wt.config.haltonerror: false
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Using 
haltonfailure from project property wt.config.haltonfailure: false
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Using 
resultpath from project property wt.config.resultpath: 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Using 
saveresponse from project property wt.config.saveresponse: true
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Using summary 
from project property wt.config.summary: true
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Creating 
result directory: 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag
   [config]  INFO (com.canoo.webtest.engine.Configuration) - Surfing with 
default browser Mozilla/4.0 (compatible; MSIE 6.0; Windows 98)
    [steps]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: steps 
(1/6)
   [invoke]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: invoke 
"get Login Page" (1/6)
   [invoke]  INFO (com.canoo.webtest.steps.request.TargetHelper) - getting 
response for url: https://ijenie.ao.dcn/jenie/iwps/myportal
   [invoke]  INFO (com.canoo.webtest.engine.WebClientContext) - Content of 
window changed to https://ijenie.ao.dcn/jenie/iwps/myportal (text/html)
   [invoke]  INFO (com.canoo.webtest.engine.WebClientContext) - Content 
loaded in newly opened window, its content will become current response
   [invoke]  INFO (com.canoo.webtest.engine.WebClientContext) - Current 
form set to none
   [invoke]  INFO (com.canoo.webtest.engine.WebClientContext) - Current 
response now: https://ijenie.ao.dcn/jenie/iwps/myportal
[verifyTitle]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: 
verifyTitle (2/6)
[selectForm]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: 
selectForm "pkmslogin" (3/6)
[selectForm]  INFO (com.canoo.webtest.engine.WebClientContext) - Current 
form set to (action=/pkmslogin.form)
[setInputField]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: 
setInputField "user" (4/6)
[setInputField]  INFO (com.canoo.webtest.steps.form.AbstractSetFieldStep) 
- Found 1 suitable fields, considering only the first one
[setInputField]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: 
setInputField "pw" (5/6)
[setInputField]  INFO (com.canoo.webtest.steps.form.AbstractSetFieldStep) 
- Found 1 suitable fields, considering only the first one
[clickButton]  INFO (com.canoo.webtest.steps.Step) - >>>> Start Step: 
clickButton (6/6)
[clickButton]  INFO (com.canoo.webtest.steps.request.ClickButton) - -> 
findTarget(by input): name=SUBMIT2 value=Log-in
[clickButton]  WARN (com.gargoylesoftware.htmlunit.html.HtmlPage) - 
Expected content type of 'application/javascript' or 
'application/ecmascript' for remotely loaded JavaScript element at 
'https://ijenie.ao.dcn/jenie/portal_dojo/v1.4.3/dojo/dojo.js', but got 
'application/x-javascript'.
[clickButton]  WARN 
(com.gargoylesoftware.htmlunit.javascript.host.HTMLDocument) - Nothing 
done for execCommand(BackgroundImageCache, ...) (feature not implemented)
 INFO (com.canoo.webtest.engine.WebClientContext) - Responses restored
 INFO (com.canoo.webtest.ant.WebtestTask) - Finished executing webtest 
"ijenieLandingPage.xml" 
(/opt/canoo/myWebTestProject/tests/JeniePortal/tests/ijenieLandingPage.xml:7: 
)
 INFO (com.canoo.webtest.reporting.XmlReporter) - Writing report to 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestReport.xml
 INFO (com.canoo.webtest.ant.WebtestTask) - Test report successfully 
created.

wt.groovyTests:
[groovyScript] Test dir for Groovy WebTest doesn't exist

wt.parallel.waitForCompletion:

wt.htmlReports.init:

wt.htmlReports:
    [mkdir] Created dir: 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/resources
     [copy] Copying 20 files to 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/resources
     [xslt] Transforming into 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results
     [xslt] Processing 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestReport.xml
 
to 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestReport.html
     [xslt] Loading stylesheet /opt/canoo/resources/WebTestReport.xsl
     [xslt] Transforming into 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results
     [xslt] Processing 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestReport.xml
 
to 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestSummary.xml
     [xslt] Loading stylesheet 
/opt/canoo/resources/WebTestReportSummaryExtractor.xsl
[groovyScript] Reading 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/001_IjenieLandingPag/WebTestSummary.xml
[groovyScript] Writing 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/WebTestOverview.xml
     [xslt] Processing 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/WebTestOverview.xml 
to /opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/index.html
     [xslt] Loading stylesheet 
/opt/canoo/resources/WebTestReportOverview.xsl

wt.openResultFile.init:

wt.openResultFile:
     [echo] Opening result file 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/index.html 
with firefox

wt.junitLikeReports:
     [xslt] Processing 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/WebTestOverview.xml 
to 
/opt/canoo/myWebTestProject/tests/JeniePortal/tests/results/WebTestOverview.junit.xml
     [xslt] Loading stylesheet 
/opt/canoo/resources/WebTestOverview2JUnit.xsl

wt.countWebtestResults:

BUILD FAILED
/opt/canoo/webtest.xml:431: 1 of 1 webtests have failed (0 successful)!






James Saxton
OIT-SDSD
Administrative Office of the United States Courts 
Remote: 908-910-5566


Reply via email to