Hi, I had a similar issue with the driver I wrote for my solar PV system. You need to change the accumulator action for your energy field. Try adding something like:
[Accumulator] [[energy]] extractor = sum to weewx.conf substituting your energy field name in place of 'energy'. Gary On Sunday, 24 March 2019 08:59:20 UTC+10, Louis De Lange wrote: > > I am busy writing a new driver to capture electricity data from a restful > service using POST requests - based heavily on the Interceptor driver. > > I have the whole think working correctly except for the incremental energy > (incEnergy) observation. Using software record generation, weewx > calculates the incEnergy observation record using the average of the loops > over the archive period, but it should add all the loop increments to > archive the sum of all the loops - similar to the way that it handles rain. > > What do I need to do force the sum of loops for archive record, rather > than the default average of the loops? > > Thanks in advance for any insight. > > Louis >