Hi,

I had a similar issue with the driver I wrote for my solar PV system. You 
need to change the accumulator action for your energy field. Try adding 
something like:

[Accumulator]
 [[energy]]
 extractor = sum


to weewx.conf substituting your energy field name in place of 'energy'.

Gary


On Sunday, 24 March 2019 08:59:20 UTC+10, Louis De Lange wrote:
>
> I am busy writing a new driver to capture electricity data from a restful 
> service using POST requests - based heavily on the Interceptor driver.
>
> I have the whole think working correctly except for the incremental energy 
> (incEnergy) observation.  Using software record generation, weewx 
> calculates the incEnergy observation record using the average of the loops 
> over the archive period, but it should add all the loop increments to 
> archive the sum of all the loops - similar to the way that it handles rain.
>
> What do I need to do force the sum of loops for archive record, rather 
> than the default average of the loops?
>
> Thanks in advance for any insight.
>
> Louis
>

Reply via email to