rtl_433 version 20.02-7-g83e3957 branch master at 202003012220 inputs file rtl_tcp RTL-SDR rtl_433 version 19.08-20-g8463f65 branch feat-atlas at 201909251947 inputs file rtl_tcp RTL-SDR had to make changes to sdr.py to get all my sensors most were the IDENTIFIER= example IDENTIFIER="Acurite Lightning 6045M" to "Acurite-6045M" to get 276M sensor i copy and paste Acurite00275MPacket class to Acurite00276MPacket class and change temperature_probe to (obj, 'temperature_1_C') and added pkt['humidity_probe'] = Packet.get_float(obj, 'humidity_1') to both the 275M and 276M are outside and inside models
using WeeWX version 4.0.0b12 i use the feat-atlas (just got the atlas sensor) here is a file i hope will help -- You received this message because you are subscribed to the Google Groups "weewx-development" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-development/e25a2822-f95d-4c83-bea0-00f28ddbe6c3%40googlegroups.com.
os: feodra 27 ---------------------------------------- DVB-T+DAB+FM+SDR RTL2832U R820T2 TCX0+BIAS T+HF V3 ---------------------------------------- installed from rpm rtl-sdr version: 0.5.4-1.fc27 rtl-sdr-devel version: 0.5.4-1.fc27 python2-pyrtlsdr version: 0.2.8-1.fc27 python3-pyrtlsdr version: 0.2.8-1.fc27 ----------------------------------------- out put from rtl_433 -M utc -M level -F json rtl_433 version 20.02-7-g83e3957 branch master at 202003012220 inputs file rtl_tcp RTL-SDR Use -h for usage help and see https://triq.org/ for documentation. Trying conf file at "rtl_433.conf"... Trying conf file at "/root/.config/rtl_433/rtl_433.conf"... Trying conf file at "/usr/local/etc/rtl_433/rtl_433.conf"... Trying conf file at "/etc/rtl_433/rtl_433.conf"... Registered 122 out of 150 device decoding protocols [ 1-4 8 11-12 15-17 19-21 23 25-26 29-36 38-60 63 67-71 73-100 102-105 108-116 119 121 124-128 130-149 ] Found Rafael Micro R820T tuner Exact sample rate is: 250000.000414 Hz [R82XX] PLL not locked! Sample rate set to 250000 S/s. Tuner gain set to Auto. Tuned to 433.920MHz. Rain Gauge model: 00899 (Access type: rain899 id: 00010949) battery is good {"time" : "2020-03-02 09:53:37", "model" : "Acurite-Rain899", "id" : 3296, "channel" : 0, "battery_ok" : 0, "rain_mm" : 926.846, "mic" : "CHECKSUM", "mod" : "ASK", "freq" : 433.943, "rssi" : -0.131, "snr" : 27.242, "noise" : -27.373} Lightning Detector Sensor model: 06045 (Access type: light id: 00000252) {"time" : "2020-03-02 09:53:32", "model" : "Acurite-6045M", "id" : 252, "channel" : "A", "battery_ok" : 1, "temperature_F" : 75.200, "humidity" : 19, "strike_count" : 110, "storm_dist" : 31, "active" : 1, "rfi" : 0, "ussb1" : 1, "exception" : 0, "raw_msg" : "c0fc6f93d1ccee5fa8", "mod" : "ASK", "freq" : 433.953, "rssi" : -0.130, "snr" : 27.700, "noise" : -27.831} Tower Senosr model: 00592TX (Access type: tower id: 00009909) {"time" : "2020-03-02 09:53:34", "model" : "Acurite-Tower", "id" : 9909, "channel" : "C", "battery_ok" : 0, "temperature_C" : 16.800, "humidity" : 33, "mic" : "CHECKSUM", "mod" : "ASK", "freq" : 433.943, "rssi" : -0.131, "snr" : 25.678, "noise" : -25.810} Indoor Temperature & Humidity Sensor model: 06044 (Access type: tower id: 00012273) with a low battery {"time" : "2020-03-02 10:21:00", "model" : "Acurite-Tower", "id" : 12273, "channel" : "C", "battery_ok" : 0, "temperature_C" : 23.000, "humidity" : 24, "mic" : "CHECKSUM", "mod" : "ASK", "freq" : 433.951, "rssi" : -0.117, "snr" : 27.404, "noise" : -27.520} subtype 0 = none, 1 = water, 2 = liquid & soil temp, 3 = spot check temp and humidity for 276M and 275M models Room Monitor: model 00276RM (With Out Water Detector model: 06010RM) (Access type: ProIn id: 00005179) {"time" : "2020-02-22 17:56:18", "model" : "Acurite-00276rm", "subtype" : 0, "id" : 5179, "battery_ok" : 1, "temperature_C" : 17.600, "humidity" : 39, "mic" : "CRC", "mod" : "ASK", "freq" : 433.905, "rssi" : -0.134, "snr" : 27.860, "noise" : -27.994} Room Monitor: model 00276RM (With Water Detector model: 06010RM) (Access type: ProIn id: 00005179) {"time" : "2020-03-02 09:53:33", "model" : "Acurite-00276rm", "subtype" : 1, "id" : 5179, "battery_ok" : 1, "temperature_C" : 18.600, "humidity" : 37, "water" : 0, "mic" : "CRC", "mic" : "CRC", "mod" : "ASK", "freq" : 433.903, "rssi" : -0.113, "snr" : 28.414, "noise" : -28.527} Room Monitor: model 00276RM (With Spot Check Temperature & Humidity Sensor model: 06012RM) (Access type: ProIn id: 00005800) with a low battery {"time" : "2020-03-02 10:02:28", "model" : "Acurite-00276rm", "subtype" : 3, "id" : 5800, "battery_ok" : 0, "temperature_C" : 26.100, "humidity" : 28, "temperature_1_C" : 24.500, "humidity_1" : 25, "mic" : "CRC", "mic" : "CRC", "mod" : "ASK", "freq" : 433.909, "rssi" : -0.100, "snr" : 25.054, "noise" : -25.154} Temperature & Humidity Monitor: model 00275RM (With Liquid & Soil Temperature Sensor: model: 06011RM) (Access type: ProOut id: 00003896) {"time" : "2020-03-02 09:53:37", "model" : "Acurite-00275rm", "subtype" : 2, "id" : 3896, "battery_ok" : 1, "temperature_C" : -7.400, "humidity" : 97, "temperature_1_C" : 0.500, "mic" : "CRC", "mic" : "CRC", "mod" : "ASK", "freq" : 433.904, "rssi" : -0.109, "snr" : 27.564, "noise" : -27.673} 5-in1 model: 06004 (Access type: 5N1 id: 00001276) {"time" : "2020-03-02 10:03:23", "model" : "Acurite-5n1", "subtype" : 49, "id" : 1276, "channel" : "A", "sequence_num" : 0, "battery_ok" : 1, "wind_avg_km_h" : 8.450, "wind_dir_deg" : 202.500, "rain_in" : 5.790, "mic" : "CHECKSUM", "mod" : "ASK", "freq" : 433.947, "rssi" : -0.113, "snr" : 24.038, "noise" : -24.151} {"time" : "2020-03-02 10:03:41", "model" : "Acurite-5n1", "subtype" : 56, "id" : 1276, "channel" : "A", "sequence_num" : 0, "battery_ok" : 1, "wind_avg_km_h" : 10.106, "temperature_F" : 19.400, "humidity" : 88, "mic" : "CHECKSUM", "mod" : "ASK", "freq" : 433.947, "rssi" : -0.118, "snr" : 25.899, "noise" : -26.016} ------------------------------------------------------------------------------------------------------------- Access firware Version 51 from access to MyAcuRite Tower Senosr model: 00592TX (Access type: tower id: 00009909) &dateutc=2019-04-28T17:31:04&id=XXXXXXXXXXXX&mt=tower&sensor=00009909&sensorbattery=normal&rssi=4&hubbattery=low&baromin=29.93&humidity=30&tempf=68.0&dewptf=35.4 5-in1 model: 06004 (Access type: 5N1 id: 00001276) &dateutc=2019-04-28T18:41:04&id=XXXXXXXXXXXX&mt=5N1&sensor=00001276&sensorbattery=normal&rssi=4&hubbattery=low&baromin=29.91&humidity=99&tempf=33.4&windspeedmph=11&winddir=113&windgustmph=14&windgustdir=90&windspeedavgmph=8&heatindex=33.4&feelslike=26.2&windchill=26.6&dewptf=33.1&dailyrainin=0.07&rainin=0.06 Indoor Temperature & Humidity Sensor model: 06044 (Access type: tower id: 00012273) with a low battery &dateutc=2020-01-12T17:56:04&id=XXXXXXXXXXXX&mt=tower&sensor=00012273&sensorbattery=low&rssi=4&hubbattery=low&baromin=29.92&humidity=22&tempf=71.7&dewptf=30.8 Room Monitor: model 00276RM (With Water Detector model: 06010RM) (Access type: ProIn id: 00005179) &dateutc=2020-01-12T17:06:04&id=XXXXXXXXXXXX&mt=ProIn&sensor=00005179&sensorbattery=normal&rssi=4&hubbattery=low&baromin=29.93&indoorhumidity=32&indoortempf=64.9&probe=1&check=0&water=0&dewptf=34.3 Room Monitor: model 00276RM (With Spot Check Temperature & Humidity Sensor model: 06012RM) (Access type: ProIn id: 00005800) &dateutc=2020-01-12T16:31:04&id=XXXXXXXXXXXX&mt=ProIn&sensor=00005800&sensorbattery=normal&rssi=4&hubbattery=low&baromin=29.94&indoorhumidity=24&indoortempf=80.7&probe=3&check=0&phumidity=20&ptempf=79.3&dewptf=40.5 Temperature & Humidity Monitor: model 00275RM (With Liquid & Soil Temperature Sensor: model: 06011RM) (Access type: ProOut id: 00003896) &dateutc=2020-01-12T18:31:04&id=XXXXXXXXXXXX&mt=ProOut&sensor=00003896&sensorbattery=normal&rssi=4&hubbattery=low&baromin=29.92&humidity=82&tempf=15.4&probe=2&check=0&ptempf=22.6&dewptf=10.9 Lightning Detector Sensor model: 06045 (Access type: light id: 00000252) &dateutc=2020-01-18T15:06:04&id=XXXXXXXXXXXX&mt=light&sensor=00000252&sensorbattery=normal&rssi=4&hubbattery=low&baromin=30.22&humidity=12&tempf=79.2&strikecount=0&interference=0&last_strike_ts=&last_strike_distance=&dewptf=22.2 ------------------------------------------------------------------------------------------------------------- rtl_433 feat-atlas Atlas model 06059 with lightning Detection Sensor (access type: Atlas Id: 00000494) out put from rtl_433 -M utc -M level -M newmodel -F json rtl_433 version 19.08-20-g8463f65 branch feat-atlas at 201909251947 inputs file rtl_tcp RTL-SDR Use -h for usage help and see https://triq.org/ for documentation. Trying conf file at "rtl_433.conf"... Trying conf file at "/root/.config/rtl_433/rtl_433.conf"... Trying conf file at "/usr/local/etc/rtl_433/rtl_433.conf"... Trying conf file at "/etc/rtl_433/rtl_433.conf"... Registered 108 out of 138 device decoding protocols [ 1-4 8 11-12 15-17 19-21 23 25-26 29-36 38-60 63 67-71 73-100 102-103 108-116 119 121 124-128 131-138 ] Found Rafael Micro R820T tuner Exact sample rate is: 250000.000414 Hz [R82XX] PLL not locked! Sample rate set to 250000 S/s. Tuner gain set to Auto. Tuned to 433.920MHz. {"time" : "2020-03-02 10:09:01", "model" : "Acurite-Atlas", "id" : 494, "channel" : "B", "sequence_num" : 0, "battery_ok" : 1, "message_type" : 37, "wind_avg_mi_h" : 4.000, "temperature_F" : 19.500, "humidity" : 88, "byte8" : 0, "byte9" : 31, "byte89" : 31, "mod" : "ASK", "freq" : 433.944, "rssi" : -0.137, "snr" : 27.094, "noise" : -27.231} {"time" : "2020-03-02 10:08:40", "model" : "Acurite-Atlas", "id" : 494, "channel" : "B", "sequence_num" : 0, "battery_ok" : 1, "message_type" : 38, "wind_avg_mi_h" : 2.000, "wind_dir_deg" : 191.000, "rain_in" : 4.110, "byte8" : 0, "byte9" : 31, "byte89" : 31, "mod" : "ASK", "freq" : 433.947, "rssi" : -0.105, "snr" : 26.725, "noise" : -26.829} {"time" : "2020-03-02 10:09:55", "model" : "Acurite-Atlas", "id" : 494, "channel" : "B", "sequence_num" : 0, "battery_ok" : 1, "message_type" : 39, "wind_avg_mi_h" : 4.000, "uv" : 0, "lux" : 0, "byte8" : 0, "byte9" : 31, "byte89" : 31, "mod" : "ASK", "freq" : 433.943, "rssi" : -0.106, "snr" : 25.318, "noise" : -25.423} ------------------------------------------------------------------------------------------------- Access firware Version 51 Atlas from access to MyAcuRite &dateutc=2020-02-27T05:46:04&id=XXXXXXXXXXXX&mt=Atlas&sensor=00000494&sensorbattery=normal&rssi=3&hubbattery=low&baromin=30.14&uvindex=0&lightintensity=0&measured_light_seconds=0&strikecount=0&interference=0&last_strike_ts=&last_strike_distance=&humidity=28&tempf=68.4&windspeedmph=0&winddir=300&windgustmph=0&windgustdir=0&windspeedavgmph=0&heatindex=66.3&feelslike=65.1&windchill=68.4&dewptf=34.0&dailyrainin=0.00&rainin=0.00
