Hi, You could have weewx do it all for you with a custom service. Have a look at the example under Adding a service <http://weewx.com/docs/customizing.htm#Adding_a_service> in the Customization Guide. It does a similar thing but uses an arbitrary expression. The example binds to the NEW_ARCHIVE_RECORD event so it uses data from the archive record, if your data of interest is in the loop packet and not the archive record then you would need to bind to the NEW_LOOP_PACKET event instead. The example sends an email, though with a bit of python nous you could have it do almost anything you want, depending on your connectivity and of course your python skills.
Gary On Monday, 10 October 2016 17:36:11 UTC+10, Ξ wrote: > > Hello, > > I have a TFA Opus station, it needs its batteries changed every now and > then, I don't live permanently where the WS is and I'm sometimes late to > replace them on time. I want a simple solution that monitors the loop for > any of the following values being '1' and alerting me somehow > 'inTempBatteryStatus': > 1, 'rainBatteryStatus': 0, 'outTempBatteryStatus': 0 > > Has anyone implemented anything similar? I'd imagine a bash script being > run for let's say half an hour each day and sifts through journalctl -f, > but not sure about the alert part. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.