If you asked weewx to calculate windchill and heatindex <http://weewx.com/docs/usersguide.htm#[[Calculations]]>, they will differ from outTemp only if certain criteria are met:
windchill: temperature must be below 50F, and wind speed above 3mph (ref: http://www.nws.noaa.gov/om/winter/windchill.shtml) heatindex: temperature must be above 80F, and relative humidity over 40% (ref: http://www.wpc.ncep.noaa.gov/html/heatindex_equation.shtml) If you asked weewx to use hardware values, then weewx uses whatever value is emitted from your Acurite. -tk On Thu, Nov 3, 2016 at 11:59 AM, Brad Tucker <[email protected]> wrote: > outTemp, windchill & heatindex are all registering the same temp. on my > system. Anyone have any ideas on where to look? When I look at the > myAcurite web display they are al different but for some reason whew is > reporting them all the same. I thought maybe the value where just drawing > on top of themselves so I decided to look in the SQLite database and sure > enough they are all exactly the same values all the time with no > differences. > > Thanks! > Brad > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > For more options, visit https://groups.google.com/d/optout. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.