Hi,

Are you sure that your station emits barometer? Corrections can only be 
applied to obs that are emitted from the hardware, this can get tricky in 
the case of pressures as there are three that are commonly used, Station 
pressure (aka pressure), Sea-Level Pressure (aka barometer) and Altimeter 
Pressure (aka altimeter). Some hardware emits one, some hardware emits one 
of the others or more than one and so it goes on. By default, if weewx is 
able to it calculates any of the missing pressures. So it can be hard to 
tell what is coming from the hardware as you may see all three in your 
output. Looking at the Hardware Guide <http://weewx.com/docs/hardware.htm> 
I see that the other Acurite models emit Station Pressure (ie pressure) and 
weewx calculates barometer and altimeter. I realise that the 1536 (if that 
is what you have - you didnt seem too sure) is not listed but....

In the absence of any other guidance you could try applying your correction 
to pressure instead of barometer. Or maybe someone with a 1536 will come 
along....

Gary

On Wednesday, 25 January 2017 15:34:08 UTC+10, BrutalGoerge wrote:
>
> I have an Acurite 01536 I believe is the number from the top of my head.
>
> The barometer needs to be increased by 0.10 for it to be correct. I get in 
> the corrections section of weewx conf and do barometer = barometer + 0.10. 
>
> Here's the weird part, after I restart weewx, the barometer shows the 
> corrected value ONCE, then after the next update in ~5 minutes, it goes 
> back down to the non-corrected value and keeps using that value.
>
> Any thoughts? 
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to