Well understanding that downloading the data stored in the hardware is a good thing (for a long time I used wview that did not have this option and every blackout for a thunderstorm I lost the rain data (I do not consider the ups a valid solution due to the elettric noise that in any case generates)), there are cases where it would be useful not to download the archived data at the reboot. For example, when for maintenance we are forced to bring the thermo-hygrometer out of the solar shield. With the davis that i also have the problem does not arise, because there is the 'setup' mode for the console that blocks data reception from iss and because, in alternative, there is the wee_device --clear-memory command. The problem instead exists for the TE923 as although documented in the help does not exist the --clear-memory command and the only way for the console to not receive data is removing the current and the batteries from the console. Very uncomfortable considering that when the power is restarted, the console starts a recovery period of 15 minutes and sometimes it is necessary to reset coordinates, altitude, dst So there is a possibility with this station (waiting for the relative driver to implement the --clear-memory command) to avoid downloading the data in the logger that are to be considered definitely wrong? thank you