Hi,

WeeWX 3.7.0 saw changes to the Vantage driver such that driver now only emits 
obs that the hardware emits. This had an effect on windGust, field windGust 
only exists in Vantage archive records not loop packets. Previously (IIRC), the 
Vantage driver emitted windGust in both loop packets and archive records. When 
you delete your database weeWX will download all available records from the 
logger memory, these records are essentially the previously generated archive 
records (not loop packets).

So what, well depending on your settings you could see the behaviour you 
describe or there could be a bug. It is not possible to say much more without 
knowing details of your config. Could you post a sanitised copy of your 
weewx.conf. You can do his directly or by using the wee_debug utility 
(http://weewx.com/docs/utilities.htm#wee_debug_utility)

Gary

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.