Hi Rich,
The US, AU and NZ Davis models hop with 51 different channel frequencies. The
EU Davis models hop with only 5 different channel frequencies.
For the first transmitter (with id=0) the hop period is 2.5 + 1/16 second, i.e.
2.5625 seconds.
One channel is this revisited after 51 * 2.5625 seconds (130.7 seconds).
During the init phase I notised long periods before your station message was
received on the channel 0.
For EU models this period is much shorter, 5 * 2.5625 is 12.8 seconds.
You might try the following US frequencies.
902381897, 902883656, 903385415, 903887174, 904388933,
904890692,
905392451, 905894210, 906395969, 906897728, 907399487,
907901246,
908403005, 908904764, 909406523, 909908282, 910410042,
910911801,
911413560, 911915319, 912417078, 912918837, 913420596,
913922355,
914424114, 914925873, 915427632, 915929391, 916431150,
916932909,
917434668, 917936427, 918438186, 918939945, 919441704,
919943463,
920445222, 920946981, 921448740, 921950499, 922452258,
922954017,
923455776, 923957535, 924459294, 924961053, 925462813,
925964572,
926466331, 926968090, 927469849,
Replace the US ones in file protocol.go and recompile the program, then start
program rtldavis to see if these frequencies are better.
BTW The US hopping sequence is OK.
Luc
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].