Awesome! Thanks. That's probably it. I did extend the schema but didn't
give temp 8 any units. I'll do that and report back.
THANKS!!!!!!!!

On Sun, Apr 21, 2019 at 6:45 PM mwall <[email protected]> wrote:

> i assume that you have already extended the schema to include extraTemp8 -
> the wview schema (which is the default schema for weewx) only goes to
> extraTemp7
>
> when you extend the schema, you must also (separately) define the units
> for the new fields that you add to the schema
>
> if you do not define units, then weewx does not know how to do any
> conversions
>
> assuming that you have a field extraTemp8 in your database,
>
> import weewx.units
> weewx.units.obs_group_dict['extraTemp8'] = 'group_temperature'
>
> the typical place to put this is in the file extensions.py in the weewx
> user directory.  you must restart weewx after making this change.
>
> see the section "assigning a unit group" in the weewx customization guide.
>
> http://weewx.com/docs/customizing.htm#Assigning_a_unit_group
>
> m
>
> --
> You received this message because you are subscribed to a topic in the
> Google Groups "weewx-user" group.
> To unsubscribe from this topic, visit
> https://groups.google.com/d/topic/weewx-user/ENXfGa40QpE/unsubscribe.
> To unsubscribe from this group and all its topics, send an email to
> [email protected].
> For more options, visit https://groups.google.com/d/optout.
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to