Wysiwyg,

Oh, then never mind.  I am surprised reboot is no help.

Do you have any other USB devices plugged in, such as any hard drives?
If so, do you have a HUB in between to supply additional power?
That can be a common issue with RPI and since all ports are on a hub behind 
what is really a single port, if any other devices are drawing too much power 
it could effect your weather station's comms.

Other than that, how long is your USB cable?
15 feet is the limit for a basic cable.  Longer than that and you need a 
powered "repeater" of sorts.  Can you try a different cable?

Regards,
\Leon
--
Leon Shaner :: Dearborn, Michigan (iPad Pro)

> On May 12, 2019, at 1:32 PM, wysiwyg <[email protected]> wrote:
> 
> Thanks for your answer Leon, but do you mean the watchdog will reboot in case 
> of usb errors?
> Because currently, reboot seems not helping in my situation. 
> 
> -- 
> You received this message because you are subscribed to the Google Groups 
> "weewx-user" group.
> To unsubscribe from this group and stop receiving emails from it, send an 
> email to [email protected].
> To view this discussion on the web visit 
> https://groups.google.com/d/msgid/weewx-user/bf72b3e0-4ca6-404c-a9e1-8c1ce4bcf2ea%40googlegroups.com.
> For more options, visit https://groups.google.com/d/optout.

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/E2708CE6-EC29-45DF-800F-ACEF6670BA1B%40isylum.org.
For more options, visit https://groups.google.com/d/optout.

Reply via email to