I forgot to add I set debug to 1 in weewx.conf and watched the syslog and still see nothing that would indicate the cause see attached file.
On Wednesday, July 3, 2019 at 6:48:34 AM UTC-4, prweather wrote: > > I am using a Peet Bros. 2100 to transfer data to CWOP > <http://www.findu.com/cgi-bin/wxpage.cgi?EW0483>. I do not have a > humidity/dp sensor only a temp sensor. Everything is working fine except no > barometer data being sent. My personal website > <http://www.perryriggle.com> is showing barometer data fine. > Using: > > - Python 2.7.15 > - weewx 3.9.1 > > I downloaded weewx_3.9.1-1_all.deb > > - xubuntu 19.04 64bit > > > Looking at the data that is being sent to CWOP from their site it shows: > > EW0483>APRS,TCPXX*,qAX,CWOP-4:@022050z3943.87N/08609.37W_262/002g005t090r000p000P000b.....h...weewx-3.9.1-Ultimeter > > Looking at restx.py indicates to me that no baro data is getting picked up > by weewx and sending the string b..... to CWOP > # Barometer: > _baro = record.get('altimeter') > if _baro is None: > _baro_str = "b....." > else: > # While everything else in the CWOP protocol is in US > Customary, > # they want the barometer in millibars. > _baro_vt = weewx.units.convert((_baro, 'inHg', > 'group_pressure'), > 'mbar') > _baro_str = "b%05d" % (_baro_vt[0] * 10.0) > > Any help would be appreciated. Thank you. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/b711968e-2ae1-40be-96fb-4381bad4ac9e%40googlegroups.com. For more options, visit https://groups.google.com/d/optout.
mylog
Description: Binary data