I followed the installation guide here:
I ran a test script like this:
import Adafruit_BME280
sensor = Adafruit_BME280.BME280(t_mode=Adafruit_BME280.BME280_OSAMPLE_8,
p_mode=Adafruit_BME280.BME280_OSAMPLE_8,
h_mode=Adafruit_BME280.BME280_OSAMPLE_8)
degrees = sensor.read_temperature()
pascals = sensor.read_pressure()
print (degrees)
print (pascals)
The output of that is:
25.034087635501418
99871.16464771295
However, when I try to get Weewx to read the data from the BME280, the
output of the syslog on a restart never gets past these lines:
Sep 29 22:55:45 raspberrypi systemd[1]: Starting LSB: weewx weather
system...
Sep 29 22:55:45 raspberrypi weewx[9610] INFO __main__: Initializing weewx
version 4.1.1
Sep 29 22:55:45 raspberrypi weewx[9610] INFO __main__: Using Python 3.7.3
(default, Jul 25 2020, 13:03:44) #012[GCC 8.3.0]
Sep 29 22:55:45 raspberrypi weewx[9610] INFO __main__: Platform
Linux-5.4.51-v7+-armv7l-with-debian-10.4
Sep 29 22:55:45 raspberrypi weewx[9610] INFO __main__: Locale is
'en_US.UTF-8'
Sep 29 22:55:45 raspberrypi weewx[9610] INFO __main__: PID file is
/var/run/weewx.pid
Sep 29 22:55:45 raspberrypi weewx[9598]: Starting weewx weather system:
weewx.
Sep 29 22:55:45 raspberrypi systemd[1]: Started LSB: weewx weather system.
In my weewx.conf, these added lines do not seem to work.
[BME280]
col_pres = pressure
col_temp = ''
sl_denominator = 0.99715048109 #
https://www.raspberrypi.org/forums/viewtopic.php?t=154262
BME280_lib_location = '/home/pi/Adafruit_Python_BME280'
[Engine]
[[Services]]
# This section specifies the services that should be run. They are
# grouped by type, and the order of services within each group
# determines the order in which the services will be run.
prep_services = weewx.engine.StdTimeSynch
data_services = ,
process_services = weewx.engine.StdConvert,
weewx.engine.StdCalibrate, weewx.engine.StdQC,
weewx.wxservices.StdWXCalculate, user.weather34.Weather34RealTime
archive_services = weewx.engine.StdArchive
restful_services = weewx.restx.StdStationRegistry,
weewx.restx.StdWunderground, weewx.restx.StdPWSweather,
weewx.restx.StdCWOP, weewx.restx.StdWOW, weewx.restx.StdAWEKAS
report_services = weewx.engine.StdPrint, weewx.engine.StdReport
# following line is the BME280 pressure sensor
data_services = user.bme280.bme
I have to comment out the BME section and the data_services line in the
Engine section in order to get Weewx to work properly again.
Any ideas on my problem?
--