Thank you again.. Ran the command suggested, *sudo /home/weewx/bin/wee_device —dump*, and output contained a slightly different message as seen below.
*raspberrypi wee_device[1516] ERROR weewx.manager: Unable to add record 2020-10-16 19:10:00 CDT (1602893400) to database 'weewx.sdb': UNIQUE constraint failed: archive.dateTime* The vantage pro2 has a couple of sensors disconnected since trying to finalize setup--unsure if that could cause above error. thank you On Thu, Oct 15, 2020 at 11:01 PM gjr80 <[email protected]> wrote: > It looks like the user you were logged in as when you ran wee_device does > not have sufficient privileges to write to the database. Try prefixing > wee_device with sudo, ie: > > $ sudo /home/weewx/bin/wee_device —dump > > Gary > > On Friday, 16 October 2020 at 13:24:18 UTC+10 [email protected] wrote: > >> Thank you again for your reply. Found the below error in the >> /var/log/syslog file for the dump command output that covered parts of >> 10/06/2020 to 10/14/2020 >> >> raspverrypi wee_device [1263] ERROR weewx.manager: Unable to add record >> 2020-10-07 14:45:00 CDT (1602099900) to database 'weewx.sdb': attempt to >> write a readonly database >> >> Used the "--dump" command today to recheck after clearing the memory >> "--clear memory" and received the same above error as yesterday. Weewx was >> stopped prior to the dump command. This error occurs every 5 minutes for >> the periods stated above and for today as well. >> Could this be corrupted memory and the reason for the catchup problem? >> Should the vantage console be powered down and reset or is there an easier >> way to solve this error? Thank you >> On Thursday, October 15, 2020 at 3:43:31 AM UTC-5 gjr80 wrote: >> >>> On Thursday, 15 October 2020 at 13:58:25 UTC+10 [email protected] >>> wrote: >>> >>>> Thank you for the replies. Yes, as stated the"no_catchup" setting does >>>> not exist in my /home/weewx/weewx.conf file. Used the setup.py method of >>>> installation using latest weewx as of 10/5/2020. Therefore based on the >>>> replies no_catchup is already set to false by default somewhere in the >>>> weewx program and therefore should attempt to catch up when offline for >>>> several days. >>> >>> >>> Correct. >>> >>> That would only leave the second reason stated in the first reply--that >>>> there is a time stamp already newer in my database that has prevented the >>>> catchup from reaching further back than this this newer time stamp. How >>>> could that be possible since the machine was started after 3 days without >>>> an ability to receive data that would include the newer time stamped data? >>> >>> >>> Hard to say. RPis are prone to time issues, particularly on startup and >>> after power outages, and it’s not unknown for a future dated record to be >>> created. Or it could some other cause/issue. >>> >>> I did stop weewx and invoke the wee_device --dump command but received >>>> the response of bash : wee_device command not found. I then tried the >>>> following command that did work: /home/weewx/util/scripts/wee_device >>>> /home/weewx/weewx.conf --dump. I was then prompted for for a yes or no >>>> which proceeded with a yes it and it dumped data through 10/07/2020 which >>>> should include data through the offline time. This data is to be placed >>>> automatically into the database file according to the documentation when >>>> using the dump command. How long does it take to show on the plot graphs >>>> (/home/weewx/public_html/index.html) which would remove the blank data line >>>> of temp, humidity etc.? >>>> >>> >>> Short answer is it depends. Data in reports should be updated on the >>> next report cycle. Data in plots depends on the plot aggregate interval >>> used in the plot, plots that include aggregates are only generated every >>> ‘aggregate interval’; current plots re-generate every report cycle, week >>> plots every hour, month every three hours and year every 24 hours. NOAA >>> format reports are a little different, the current month and year reports >>> are updated every report cycle. Historical NOAA format month and year >>> reports are never re-generated. The easiest way to force and update of the >>> NOAA format reports is to delete all of the generated reports, this will >>> cause all NOAA format reports to be re-generated on the next report cycle. >>> A similar approach can be taken with the plots by deleting the generated >>> plot files to force all plots to be re-generated on the next report cycle. >>> >>> >>>> Does dumping the data clear the memory of the data logger or is it >>>> still there as well as now on my dump file? >>>> >>> >>> No, —dump just reads all of the stored archive records and attempts to >>> save them to archive. —clear-memory will clear the logger memory. >>> >>> >>>> Incidentally, should the full paths have been needed to invoke the >>>> wee_device command. >>>> >>> >>> setup.py installs typically require you to be in the directory >>> containing the executable (in this case wee_device) or to use an >>> appropriate path to the executable. Package installs usually don’t require >>> the path as the appropriate directory is added to the PATH environment >>> variable on installation. And we probably don’t help too much as we tend >>> not to mention adding the path when listing commands, probably a bit of >>> assumed knowledge there as well. >>> >>> >>>> Thank you and my apologies for so many questions. >>>> >>> >>> No problems, we’ve all been in your shoes at some time or other. >>> >>> Gary >>> >> -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > To view this discussion on the web visit > https://groups.google.com/d/msgid/weewx-user/8529a7da-5b5c-4433-8681-2c50e4eaaad5n%40googlegroups.com > <https://groups.google.com/d/msgid/weewx-user/8529a7da-5b5c-4433-8681-2c50e4eaaad5n%40googlegroups.com?utm_medium=email&utm_source=footer> > . > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/CAGW8XMTv2Hc6N%3DBFfUH3F2SnSBhrPTtykoSeyJYP-Jt72ND1PQ%40mail.gmail.com.