Hi Mark,
Does the user, that weewx is running as, belong to the group dialout ?
On linux, a user that wants to use a serial port must belong to the
dialout group.
This still applies even if the serial port is via a USB interface.
regards
Tim
On 26/10/20 7:06 am, Mark Jenks wrote:
I just did a full stop and start, and I get this. Permissions?
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** Vantage.__init__(self,
**config_dict[DRIVER_NAM>
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** File
"/home/weewx/bin/weewx/drivers/vantage.py", >
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** self.port.openPort()
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** File
"/home/weewx/bin/weewx/drivers/vantage.py", >
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** self.serial_port =
serial.Serial(self.port, sel>
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
weewx.engine: **** AttributeError: module 'serial' has no
attribute 'S>
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
__main__: Unable to load driver: module 'serial' has no attribute 'Serial'
Oct 25 15:04:18 server.mjenks.net weewxd[20245]: weewx[20245] CRITICAL
__main__: **** Exiting...
Oct 25 15:04:18 server.mjenks.net systemd[1]: weewx.service: Main
process exited, code=exited, status=4/NOPERMISSION
Oct 25 15:04:18 server.mjenks.net systemd[1]: weewx.service: Failed
with result 'exit-code'.
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion on the web visit
https://groups.google.com/d/msgid/weewx-user/60b41623-1158-530c-f994-aae0130d94b9%40skybase.net.