Hi,

I presume you meant 4.3.0 since there is no 4.0.3. As per the User Guide 
<http://weewx.com/docs/usersguide.htm#%5B%5B%5Bheatindex%5D%5D%5D> have you 
tried:

[StdWXCalculate]
    [[WXXTypes]]
        [[[heatindex]]]
            algorithm = old

Gary
On Tuesday, 12 January 2021 at 19:29:24 UTC+10 [email protected] wrote:

> I have updated to v4.0.3 (setup.py method) and I want to calculate heat 
> index using the "old" NWS algorithm. In my weewx.conf I have added:
>
> [StdWXCalculate]
>     [[Algorithms]]
>         heatindex = old
>
> but this doesn't seem to have any effect. From looking at wxformulas.py I 
> had assume that setting the algorithm value to anything other than "new" 
> would work. Can anyone advise what I need to do to get this working?
> Thanks!  
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/ad86da5a-2639-4692-9494-ce6acffbe99an%40googlegroups.com.

Reply via email to