I have been trying for a week to get the live updates to work for Weewx. 
But I am not having any luck at all, so can someone please help if they can 
see where my setup is wrong. For background info: Weewx is running on an 
RPi 4B 192.168.8.155. I have set up an RPi 3A as the MQTT Broker 
192.168.8.158. The "service weewx status" shows the following:

 *Mar 21 12:40:23 RPi-weather python3[2185]: weewx[2185] ERROR weewx.restx: 
MQTT: Failed to publish record 2021-03-21 11*

 The Belchertown page shows:

*"Connected. Waiting for data. Last Updated 21 March 2021 yada yada"*

My Weewx.conf setup is as follows:

 















*188     [[MQTT]] 189         server_url = 
mqtt://vantagepro:[email protected]:1833/ 190         topic = 
weather 191         unit_system = METRIC 192         binding = archive,loop 
193         aggregation = aggregate 248     [[Belchertown]] 249         
skin = Belchertown 250         HTML_ROOT = /var/www/html 251          
[[Services]] 669           674         restful_services = 
weewx.restx.StdStationRegistry,......, user.mqtt.MQTT*

 

I have not set up SSL on the Broker, hence it is disabled.   
/etc/weewx/skins/Belchertown/skin.conf 
is as follows:








*35     # MQTT Websockets 36     mqtt_websockets_enabled = 1 37     
mqtt_websockets_host = 192.168.8.158 38     mqtt_websockets_port = 9001 
39     mqtt_websockets_ssl = 0 40     mqtt_websockets_topic = weather/loop 
41     disconnect_live_website_visitor = 1800000*

 

The MQTT (192.168.8.158) broker.conf is:

 
















* 6 pid_file /run/mosquitto/mosquitto.pid  7  8 persistence true  9 
persistence_location /var/lib/mosquitto/ 10 11 log_dest file 
/var/log/mosquitto/mosquitto.log 12 13 log_type all 14 log_facility 5 15 
log_type error 16 log_type warning 17 log_type notice 18 log_type 
information 19 20 connection_messages true 21 log_timestamp true 22 23 
include_dir /etc/mosquitto/conf.d*

and the Broker/conf.d/myconfig.conf












*# mqtt listener 1883 protocol mqtt # websockets listener 9001 protocol 
websockets #Allow anonymous to read only and others need to be set in 
passwd,acl allow_anonymous true password_file /etc/mosquitto/passwd 
acl_file /etc/mosquitto/acl*

 

The Broker Pub/Sub is working with and without passwords, using terminals 
in Weewx RPi (192.168.8.155).

The Mosquitto client on the Weewx machine (192.168.8.155) has no 
configuration file

 

I know I have something wrong but I just have no idea.

 

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/766ba089-dc64-4a9f-82cf-4e06f7ddd827n%40googlegroups.com.