Hi,

Nothing to do with drivers or extensions, it’s a font issue. Have a read of 
the section Funky symbols in plots 
<http://weewx.com/docs/usersguide.htm#funky_symbols> in the User’s Guide.

Gary
On Tuesday, 6 April 2021 at 07:31:17 UTC+10 [email protected] wrote:

> This is a minor annoyance, but I am failing to figure out where this is 
> being done, or how to fix it.  Units for PM2.5 are micrograms per meter 
> cubed.  I've got a "current" where the units look as expected: µg/m³.
>
> But in the generated history images, the units in the upper show as shown 
> in this image: [image: Screen Shot 2021-04-05 at 2.27.13 PM.png]
> Station data is coming from the WX1000 extension and in this case, some of 
> it from the PurpleAir extension.  Looking through both extensions, I am not 
> seeing who/what is choosing the unit string for these values, nor where 
> it's getting sucked into the image generator.  Hints?  I am a week into 
> using WeeWX, and am quite impressed, but finding where the bodies are 
> buried for this sort of magic.
>
> --Richard
>
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/42477310-4410-48f7-a51d-37a99c1e59a1n%40googlegroups.com.

Reply via email to