The thread you linked describes the process to (1) have WeeWX use a clean 
database and (2) change the driver from simulator to FineOffsetUSB (fousb). 
Step 3 was all about the latter, it has nothing to do with clearing the 
database. If you simply want to have WeeWX start with a clean database then 
the easiest thing to do is to stop weewx, delete the database file (a 
default install will use database weewx.sdb located in either 
/var/lib/weewx or /home/weewx/archive) and then restart WeeWX. WeeWX will 
automatically create a clean database during startup. Unless you have 
manually changed the structure of your archive this will give you a clean 
database with the same structure (schema) as the original.

Of course if you want to keep the old database/data you should make a copy 
of the database before deleting.

Gary

On Wednesday, 5 May 2021 at 05:14:38 UTC+10 [email protected] wrote:

> Have started operation of WeeWX with the Simulator.
> Now switched to Tempest, and getting real data.
>
> The thread 
> https://groups.google.com/g/weewx-user/c/NJ_XFLbWrNc/m/fpRqGIBWBQAJ 
> describes a method to transition the database(s) from Simulator to 'Real' 
> sensor by defining completely new database(s).
> But what is the easy way to *wipe *the data in the database(s) *while* 
> maintaining the datastructure?
> In other words:
> can the goal be achieved with less action than redefinition according to 
> steps 2.+3. in the quoted message?
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/53cc57b3-946c-4c63-a03f-be2b443386fdn%40googlegroups.com.

Reply via email to