*"Is it possible to have weewx ignore these elements and only process the "CO2_Value_PPM": 419 ?" *Yes, Rich provided the possible solution.
* "I'm not sure what "float" does but mayve that's a problem...?" *A float is a real number. It is trying to convert 'report_telemetry' which is a string to a real number causing the failure. On Monday, November 29, 2021 at 9:05:54 PM UTC-5 [email protected] wrote: > Bob, > You are correct. The extra data is causing the problem. Due to a poor > early design decision, MQTTSubscribe defaults to converting everything to > float. Obviously, 'report_telemetry' cannot be converted to float. The > following configuration should work. It ignores all but 'CO2_Value_PPM'. > [[topics]] > [[[mytopic]]] > ignore = true > [[[[CO2_Value_PPM]]]] > name = co2 > ignore = false > If that doesn't work, let me know and I can give a different configuration. > rich > > On Monday, 29 November 2021 at 19:53:46 UTC-5 [email protected] wrote: > >> Last post of the day, I promise! >> I think the node-red flow is working the way it should and reporting the >> parsed message as in my last post. >> >> weewx.conf configuration (changed topic to "mytopic" in the flow and in >> weewx). >> >> [MQTTSubscribeService] >> # This section is for the MQTTSubscribe service. >> enable = true # false >> >> # The MQTT server. >> # Default is localhost. >> host = localhost >> port = 1883 >> keepalive = 60 >> >> username = None #admin #None >> password = None #admin #None >> binding = loop >> >> [[message_callback]] >> type = json #REPLACE_ME >> >> # mytopic is the topic to subscribe to. >> [[topics]] >> >> unit_system = US >> >> [[[mytopic]]] >> >> #data sent from RAK7244 >> #ignore = true >> [[[[CO2_Value_PPM]]]] >> #weewx db field name >> name = co2 >> ignore = false >> contains total = false >> conversion type = float >> #units = ppm >> #[[[SECOND/REPLACE_ME]]] >> >> *This is the weewx.log debug info:* >> >> Nov 29 19:20:58 n4mrv weewx[17143] DEBUG user.MQTTSubscribe: (Service) >> MessageCallbackProvider data-> incoming topic: mytopic, QOS: 0, retain: 0, >> payload: b'{\n "CO2_Value_PPM": 419,\n "measurementId": 4100,\n >> "type": "report_telemetry"\n}' >> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) >> MessageCallbackProvider on_message_json failed with <class >> 'user.MQTTSubscribe.ConversionError'> and reason Failed converting field >> type with value report_telemetry using 'lambda x: to_float(x)' with reason >> could not convert string to float: 'report_telemetry'.. >> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) >> **** MessageCallbackProvider Ignoring topic=mytopic and payload=b'{\n >> "CO2_Value_PPM": 419,\n "measurementId": 4100,\n "type": >> "report_telemetry"\n}' >> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) >> **** MessageCallbackProvider Traceback (most recent call last):#012 File >> "/home/weewx/bin/user/MQTTSubscribe.py", line 1263, in _convert_value#012 >> return conversion_func['compiled'](value)#012 File "<string>", line 1, in >> <lambda>#012 File "/home/weewx/bin/weeutil/weeutil.py", line 1276, in >> to_float#012 return float(x) if x is not None else None#012ValueError: >> could not convert string to float: 'report_telemetry'#012#012During >> handling of the above exception, another exception >> occurred:#012#012Traceback (most recent call last):#012 File >> "/home/weewx/bin/user/MQTTSubscribe.py", line 1427, in _on_message_json#012 >> (fieldname, value) = self._update_data(fields, fields_conversion_func, >> lookup_key, data_flattened[key], unit_system)#012 File >> "/home/weewx/bin/user/MQTTSubscribe.py", line 1230, in _update_data#012 >> value = self._convert_value(fields, default_field_conversion_func, >> orig_name, orig_value)#012 File "/home/weewx/bin/user/MQTTSubscribe.py", >> line 1268, in _convert_value#012 raise ConversionError("Failed >> converting field %s with value %s using '%s' with reason %s." >> \#012user.MQTTSubscribe.ConversionError: Failed converting field type with >> value report_telemetry using 'lambda x: to_float(x)' with reason could not >> convert string to float: 'report_telemetry'. >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: >> new_loop_packet(Event type: <class 'weewx.NEW_LOOP_PACKET'> | packet: >> {'dateTime': 1638231660, 'usUnits': 1, 'barometer': 30.091, 'inTemp': 79.0, >> 'inHumidity': 27.0, 'outTemp': 33.7, 'windSpeed': 0.0, 'windSpeed10': 0.0, >> 'windDir': 0, 'extraTemp1': 72.0, 'soilTemp1': 51.0, 'soilTemp2': 97.0, >> 'soilTemp4': 47.0, 'leafTemp1': 51.0, 'leafTemp2': 97.0, 'outHumidity': >> 74.0, 'rainRate': 0.0, 'UV': 0.0, 'radiation': 0.0, 'stormRain': 0.0, >> 'dayRain': 0.0, 'monthRain': 0.6, 'yearRain': 41.65, 'dayET': 0.051, >> 'monthET': 1.15, 'yearET': 24.95, 'leafWet4': 0.0, 'insideAlarm': 0, >> 'rainAlarm': 0, 'outsideAlarm1': 0, 'outsideAlarm2': 0, 'extraAlarm1': 0, >> 'extraAlarm2': 0, 'extraAlarm3': 0, 'extraAlarm4': 0, 'extraAlarm5': 0, >> 'extraAlarm6': 0, 'extraAlarm7': 0, 'extraAlarm8': 0, 'soilLeafAlarm1': 0, >> 'soilLeafAlarm2': 0, 'soilLeafAlarm3': 0, 'soilLeafAlarm4': 0, >> 'txBatteryStatus': 0, 'consBatteryVoltage': 4.72, 'forecastIcon': 6, >> 'forecastRule': 44, 'sunrise': 1638187560, 'sunset': 1638222720, 'rain': >> 0.0, 'windGust': 0.0, 'windGustDir': None}) >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: new_loop_packet: >> self.cfg.concentrations: Concentrations(timestamp=1638231655, pm1_0=4.425, >> pm10_0=6.5649999999999995, pm2_5_cf_1=5.39, pm2_5_cf_1_b=7.39, >> current_temp_f=42, current_humidity=45) >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Time of reading >> being inserted: 2021-11-29 19:20:55 EST (1638231655) >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted >> packet[pm1_0]: 4.425000 into packet. >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted >> packet[pm2_5]: 4.534270 into packet. >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted >> packet[pm10_0]: 6.565000 into packet. >> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.MQTTSubscribe: (Service) >> data-> final packet is 2021-11-29 19:21:00 EST (1638231660): barometer: >> 30.091, consBatteryVoltage: 4.72, dateTime: 1638231660, dayET: 0.051, >> dayRain: 0.0, extraAlarm1: 0, extraAlarm2: 0, extraAlarm3: 0, extraAlarm4: >> 0, extraAlarm5: 0, extraAlarm6: 0, extraAlarm7: 0, extraAlarm8: 0, >> extraTemp1: 72.0, forecastIcon: 6, forecastRule: 44, inHumidity: 27.0, >> insideAlarm: 0, inTemp: 79.0, leafTemp1: 51.0, leafTemp2: 97.0, leafWet4: >> 0.0, monthET: 1.15, monthRain: 0.6, outHumidity: 74.0, outsideAlarm1: 0, >> outsideAlarm2: 0, outTemp: 33.7, pm1_0: 4.425, pm10_0: 6.5649999999999995, >> pm2_5: 4.53427, pm2_5_aqi: 18.75, pm2_5_aqi_color: 32768, radiation: 0.0, >> rain: 0.0, rainAlarm: 0, rainRate: 0.0, soilLeafAlarm1: 0, soilLeafAlarm2: >> 0, soilLeafAlarm3: 0, soilLeafAlarm4: 0, soilTemp1: 51.0, soilTemp2: 97.0, >> soilTemp4: 47.0, stormRain: 0.0, sunrise: 1638187560, sunset: 1638222720, >> txBatteryStatus: 0, usUnits: 1, UV: 0.0, windDir: 0, windGust: 0.0, >> windGustDir: None, windSpeed: 0.0, windSpeed10: 0.0, yearET: 24.95, >> yearRain: 41.65 >> >> It seems that there is something wrong with the format coming into weewx >> from the flow. It may be confused by the other two >> elements "measurementId": 4100, and "type": "report_telemetry" which cause >> the whole thing to fail. Is it possible to have weewx ignore these elements >> and only process the "CO2_Value_PPM": 419 ? I'm not sure what "float" does >> but mayve that's a problem...? >> Thanks again and I'll have another look tomorrow. >> Cheers, >> Bob >> On Monday, November 29, 2021 at 5:38:37 PM UTC-5 vince wrote: >> >>> On Monday, November 29, 2021 at 2:05:05 PM UTC-8 [email protected] wrote: >>> >>>> I removed the function and it looks better. Last debug going into >>>> mqtt_publish: >>>> >>>> 11/29/2021, 4:17:17 PMnode: mqtt_payload >>>> <http://localhost:1880/#>application/18/device/2cf7f12122500013/rx >>>> : msg.payload : string[87] >>>> string[87] >>>> { "CO2_Value_PPM": 399, "measurementId": 4100, "type": >>>> "report_telemetry" } >>>> <http://localhost:1880/#> >>>> >>>> However, weewx still doesn't seem to like it. I'll try changing topics >>>> to "mytopic" and see what happens. >>>> >>> >>> Sigh - just set the topic in weewx.conf to whatever you are publishing >>> via node-red, and reset weewx. >>> Until you do that, it's not going to work. >>> >>> It does not matter what topic you publish to, just keep your naming >>> consistent and theoretically relevant so you can figure it out a year from >>> now when you want to decipher what the heck you did :-) >>> >>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/c8cbe805-a7cb-405a-953a-94c99d376be7n%40googlegroups.com.