*"Is it possible to have weewx ignore these elements and only process the  
"CO2_Value_PPM": 419 ?"  *Yes, Rich provided the possible solution.

* "I'm not sure what "float" does but mayve that's a problem...?"  *A float 
is a real number.  It is trying to convert  'report_telemetry' which is a 
string to a real number causing the failure.

On Monday, November 29, 2021 at 9:05:54 PM UTC-5 [email protected] wrote:

> Bob,
> You are correct. The extra data is causing the problem. Due to a poor 
> early design decision, MQTTSubscribe defaults to converting everything to 
> float. Obviously, 'report_telemetry' cannot be converted to float. The 
> following configuration should work. It ignores all but 'CO2_Value_PPM'.
>     [[topics]]
>         [[[mytopic]]]
>             ignore = true
>             [[[[CO2_Value_PPM]]]]
>                 name = co2
>                 ignore = false
> If that doesn't work, let me know and I can give a different configuration.
> rich
>
> On Monday, 29 November 2021 at 19:53:46 UTC-5 [email protected] wrote:
>
>> Last post of the day, I promise!
>> I think the node-red flow is working the way it should and reporting the 
>> parsed message as in my last post.
>>
>> weewx.conf configuration (changed topic to "mytopic" in the flow and in 
>> weewx).
>>
>> [MQTTSubscribeService]
>>     # This section is for the MQTTSubscribe service.
>>     enable = true    # false
>>
>>     # The MQTT server.
>>     # Default is localhost.
>>     host = localhost
>>         port = 1883
>>         keepalive = 60
>>
>>         username = None #admin    #None
>>        password = None  #admin    #None
>>       binding = loop
>>
>>        [[message_callback]]
>>                 type = json    #REPLACE_ME
>>
>>     #  mytopic  is the topic to subscribe to.
>>     [[topics]]
>>        
>>         unit_system = US
>>
>>         [[[mytopic]]]
>>
>>         #data  sent from RAK7244
>>         #ignore = true
>>                 [[[[CO2_Value_PPM]]]]
>>         #weewx db field name
>>                 name = co2
>>                 ignore = false
>>                 contains total = false
>>                 conversion type = float
>>                 #units = ppm
>>         #[[[SECOND/REPLACE_ME]]]
>>
>> *This is the weewx.log debug info:*
>>
>> Nov 29 19:20:58 n4mrv weewx[17143] DEBUG user.MQTTSubscribe: (Service) 
>> MessageCallbackProvider data-> incoming topic: mytopic, QOS: 0, retain: 0, 
>> payload: b'{\n    "CO2_Value_PPM": 419,\n    "measurementId": 4100,\n   
>>  "type": "report_telemetry"\n}'
>> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) 
>> MessageCallbackProvider on_message_json failed with <class 
>> 'user.MQTTSubscribe.ConversionError'> and reason Failed converting field 
>> type with value report_telemetry using 'lambda x: to_float(x)' with reason 
>> could not convert string to float: 'report_telemetry'..
>> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) 
>> **** MessageCallbackProvider Ignoring topic=mytopic and payload=b'{\n   
>>  "CO2_Value_PPM": 419,\n    "measurementId": 4100,\n    "type": 
>> "report_telemetry"\n}'
>> Nov 29 19:20:58 n4mrv weewx[17143] ERROR user.MQTTSubscribe: (Service) 
>> **** MessageCallbackProvider Traceback (most recent call last):#012  File 
>> "/home/weewx/bin/user/MQTTSubscribe.py", line 1263, in _convert_value#012   
>>  return conversion_func['compiled'](value)#012  File "<string>", line 1, in 
>> <lambda>#012  File "/home/weewx/bin/weeutil/weeutil.py", line 1276, in 
>> to_float#012    return float(x) if x is not None else None#012ValueError: 
>> could not convert string to float: 'report_telemetry'#012#012During 
>> handling of the above exception, another exception 
>> occurred:#012#012Traceback (most recent call last):#012  File 
>> "/home/weewx/bin/user/MQTTSubscribe.py", line 1427, in _on_message_json#012 
>>    (fieldname, value) = self._update_data(fields, fields_conversion_func, 
>> lookup_key, data_flattened[key], unit_system)#012  File 
>> "/home/weewx/bin/user/MQTTSubscribe.py", line 1230, in _update_data#012   
>>  value = self._convert_value(fields, default_field_conversion_func, 
>> orig_name, orig_value)#012  File "/home/weewx/bin/user/MQTTSubscribe.py", 
>> line 1268, in _convert_value#012    raise ConversionError("Failed 
>> converting field %s with value %s using '%s' with reason %s." 
>> \#012user.MQTTSubscribe.ConversionError: Failed converting field type with 
>> value report_telemetry using 'lambda x: to_float(x)' with reason could not 
>> convert string to float: 'report_telemetry'.
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: 
>> new_loop_packet(Event type: <class 'weewx.NEW_LOOP_PACKET'> | packet: 
>> {'dateTime': 1638231660, 'usUnits': 1, 'barometer': 30.091, 'inTemp': 79.0, 
>> 'inHumidity': 27.0, 'outTemp': 33.7, 'windSpeed': 0.0, 'windSpeed10': 0.0, 
>> 'windDir': 0, 'extraTemp1': 72.0, 'soilTemp1': 51.0, 'soilTemp2': 97.0, 
>> 'soilTemp4': 47.0, 'leafTemp1': 51.0, 'leafTemp2': 97.0, 'outHumidity': 
>> 74.0, 'rainRate': 0.0, 'UV': 0.0, 'radiation': 0.0, 'stormRain': 0.0, 
>> 'dayRain': 0.0, 'monthRain': 0.6, 'yearRain': 41.65, 'dayET': 0.051, 
>> 'monthET': 1.15, 'yearET': 24.95, 'leafWet4': 0.0, 'insideAlarm': 0, 
>> 'rainAlarm': 0, 'outsideAlarm1': 0, 'outsideAlarm2': 0, 'extraAlarm1': 0, 
>> 'extraAlarm2': 0, 'extraAlarm3': 0, 'extraAlarm4': 0, 'extraAlarm5': 0, 
>> 'extraAlarm6': 0, 'extraAlarm7': 0, 'extraAlarm8': 0, 'soilLeafAlarm1': 0, 
>> 'soilLeafAlarm2': 0, 'soilLeafAlarm3': 0, 'soilLeafAlarm4': 0, 
>> 'txBatteryStatus': 0, 'consBatteryVoltage': 4.72, 'forecastIcon': 6, 
>> 'forecastRule': 44, 'sunrise': 1638187560, 'sunset': 1638222720, 'rain': 
>> 0.0, 'windGust': 0.0, 'windGustDir': None})
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: new_loop_packet: 
>> self.cfg.concentrations: Concentrations(timestamp=1638231655, pm1_0=4.425, 
>> pm10_0=6.5649999999999995, pm2_5_cf_1=5.39, pm2_5_cf_1_b=7.39, 
>> current_temp_f=42, current_humidity=45)
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Time of reading 
>> being inserted: 2021-11-29 19:20:55 EST (1638231655)
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted 
>> packet[pm1_0]: 4.425000 into packet.
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted 
>> packet[pm2_5]: 4.534270 into packet.
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.purple: Inserted 
>> packet[pm10_0]: 6.565000 into packet.
>> Nov 29 19:20:59 n4mrv weewx[17143] DEBUG user.MQTTSubscribe: (Service) 
>> data-> final packet is 2021-11-29 19:21:00 EST (1638231660): barometer: 
>> 30.091, consBatteryVoltage: 4.72, dateTime: 1638231660, dayET: 0.051, 
>> dayRain: 0.0, extraAlarm1: 0, extraAlarm2: 0, extraAlarm3: 0, extraAlarm4: 
>> 0, extraAlarm5: 0, extraAlarm6: 0, extraAlarm7: 0, extraAlarm8: 0, 
>> extraTemp1: 72.0, forecastIcon: 6, forecastRule: 44, inHumidity: 27.0, 
>> insideAlarm: 0, inTemp: 79.0, leafTemp1: 51.0, leafTemp2: 97.0, leafWet4: 
>> 0.0, monthET: 1.15, monthRain: 0.6, outHumidity: 74.0, outsideAlarm1: 0, 
>> outsideAlarm2: 0, outTemp: 33.7, pm1_0: 4.425, pm10_0: 6.5649999999999995, 
>> pm2_5: 4.53427, pm2_5_aqi: 18.75, pm2_5_aqi_color: 32768, radiation: 0.0, 
>> rain: 0.0, rainAlarm: 0, rainRate: 0.0, soilLeafAlarm1: 0, soilLeafAlarm2: 
>> 0, soilLeafAlarm3: 0, soilLeafAlarm4: 0, soilTemp1: 51.0, soilTemp2: 97.0, 
>> soilTemp4: 47.0, stormRain: 0.0, sunrise: 1638187560, sunset: 1638222720, 
>> txBatteryStatus: 0, usUnits: 1, UV: 0.0, windDir: 0, windGust: 0.0, 
>> windGustDir: None, windSpeed: 0.0, windSpeed10: 0.0, yearET: 24.95, 
>> yearRain: 41.65
>>
>> It seems that there is something wrong with the format coming into weewx 
>> from the flow. It may be confused by the other two 
>> elements "measurementId": 4100, and "type": "report_telemetry" which cause 
>> the whole thing to fail. Is it possible to have weewx ignore these elements 
>> and only process the  "CO2_Value_PPM": 419 ? I'm not sure what "float" does 
>> but mayve that's a problem...?
>> Thanks again and I'll have another look tomorrow.
>> Cheers,
>> Bob
>> On Monday, November 29, 2021 at 5:38:37 PM UTC-5 vince wrote:
>>
>>> On Monday, November 29, 2021 at 2:05:05 PM UTC-8 [email protected] wrote:
>>>
>>>> I removed the function and it looks better. Last debug going into 
>>>> mqtt_publish:
>>>>
>>>> 11/29/2021, 4:17:17 PMnode: mqtt_payload 
>>>> <http://localhost:1880/#>application/18/device/2cf7f12122500013/rx 
>>>> : msg.payload : string[87]
>>>> string[87]
>>>> { "CO2_Value_PPM": 399, "measurementId": 4100, "type": 
>>>> "report_telemetry" }
>>>> <http://localhost:1880/#>
>>>>
>>>> However, weewx still doesn't seem to like it. I'll try changing topics 
>>>> to "mytopic" and see what happens.
>>>>
>>>
>>> Sigh - just set the topic in weewx.conf to whatever you are publishing 
>>> via node-red, and reset weewx.
>>> Until you do that, it's not going to work.
>>>
>>> It does not matter what topic you publish to, just keep your naming 
>>> consistent and theoretically relevant so you can figure it out a year from 
>>> now when you want to decipher what the heck you did :-)
>>>
>>>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/c8cbe805-a7cb-405a-953a-94c99d376be7n%40googlegroups.com.

Reply via email to