Just as a matter of interest, I went back even further and looked at my original Vantage Pro (not 2) with firmware "REV B MAR 30 2004".
I'm seeing the soilLeafAlarms but not leafWet in the LOOP data. I don't push to Weatherlink or publish online at all, I just use WeeWX to download the archive data from the logger and produce reports (particularly NOAA) to keep my own historical records locally. Works great for me. Manufacture code: B30407A83A LOOP: 2022-02-26 21:14:24 MST (1645935264) 'altimeter': '30.257678000000002', 'appTemp': '-6.179805913900935', 'barometer': '30.257678000000002', 'cloudbase': '1571.5926270879713', 'consBatteryVoltage': '4.75', 'dateTime': '1645935264', 'dayET': '0.0', 'dayRain': '0.0', 'dewpoint': '-4.9150075591870745', 'ET': 'None', 'extraAlarm1': '0', 'extraAlarm2': '0', 'extraAlarm3': '0', 'extraAlarm4': '0', 'extraAlarm5': '0', 'extraAlarm6': '0', 'extraAlarm7': '0', 'extraAlarm8': '0', 'extraTemp1': '43.0', 'forecastIcon': '8', 'forecastRule': '1', 'heatindex': '2.0', 'humidex': '1.9999999999999964', 'inDewpoint': '27.247736039588684', 'inHumidity': '24.0', 'insideAlarm': '0', 'inTemp': '64.9', 'maxSolarRad': 'None', 'monthET': '0.0', 'monthRain': '0.0', 'outHumidity': '72.0', 'outsideAlarm1': '0', 'outsideAlarm2': '0', 'outTemp': '2.0', 'pressure': '23.188788492606', 'rain': '0.0', 'rainAlarm': '0', 'rainRate': '0.0', '*soilLeafAlarm1': '0', 'soilLeafAlarm2': '0', 'soilLeafAlarm3': '0', 'soilLeafAlarm4': '0',* 'stormRain': '0.0', 'sunrise': '1645883880', 'sunset': '1645923900', 'txBatteryStatus': '0', 'usUnits': '1', 'windchill': '2.0', 'windDir': '162.0', 'windGust': '3.0', 'windGustDir': '162.0', 'windrun': 'None', 'windSpeed': '3.0', 'windSpeed10': '2.0', 'yearET': '0.0', 'yearRain': '0.0' On Saturday, February 26, 2022 at 1:41:32 PM UTC-7 vince wrote: > On Saturday, February 26, 2022 at 12:01:07 PM UTC-8 Tom Keffer wrote: > >> Now that you mention it, I see much the same thing on my vintage VP2. >> > However, the archive records are fine. If you use hardware record >> generation (the default), then the values should not get into the database >> at all. >> >> So, Tom & VInce, I suspect this is a different issue, if it's an issue at >> all. >> > > Think it's a different issue. The extra leafWet4 and soilLeafAlarm1-4 > items we see on VP2 aren't even in the extended schema so we might just be > getting lucky there. Given my firmware is over 13 years old, whatever's > going on has been there for a long time.... > > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/f601b966-0862-4400-930b-f8e3cb073281n%40googlegroups.com.