This is solving the issue!

Thanks a lot, Tom!

On Wednesday, 23 March 2022 at 13:33:14 UTC+1 [email protected] wrote:

> It looks like it (and lowOutTemp) were never assigned to a unit group. 
>
> Fixed in commit a55892e 
> <https://github.com/weewx/weewx/commit/a55892e1d5cd41167d7eff9635f5a1750ad2a850>
> .
>
> You can either patch your copy of weewx/units.py, or download a fresh one 
> <https://raw.githubusercontent.com/weewx/weewx/a55892e1d5cd41167d7eff9635f5a1750ad2a850/bin/weewx/units.py>
> .
>
> On Wed, Mar 23, 2022 at 1:04 AM Saverio Guzzo <[email protected]> wrote:
>
>> Hi Tom,
>>
>> Using the function *weewx.units.to_METRICWX *is working well for all the 
>> fields but *highOutTemp*, which keeps still being reported in 
>> Fahrenheit. Would you have any ideas on the reason for this?
>>
>> Thanks again!
>> Saverio
>> On Wednesday, 23 February 2022 at 13:23:00 UTC+1 Saverio Guzzo wrote:
>>
>>> Wow, thanks Tom!
>>> Such an excellent program!
>>>
>>> SG
>>>
>>> On Monday, 21 February 2022 at 18:01:52 UTC [email protected] wrote:
>>>
>>>> The Vantage series reports measurements in the US Customary unit 
>>>> system. Because you are printing packets directly from the driver, that's 
>>>> what you're going to get.
>>>>
>>>> One thing you can do is take advantage of one of the functions in 
>>>> units.py. Try this:
>>>>
>>>> import weewx.units
>>>> for packet in vantage.genDavisArchiveRecords(since_ts):
>>>>     new_packet = weewx.units.to_METRICWX(packet)
>>>>     print(new_packet)
>>>>
>>>>
>>>>
>>>> On Mon, Feb 21, 2022 at 6:40 AM Saverio Guzzo <[email protected]> 
>>>> wrote:
>>>>
>>>>> Hello community!
>>>>>
>>>>> I'm using the vantage's driver as a standalone program and I'm 
>>>>> wondering if there is an way to convert the measurements to the metric 
>>>>> system.
>>>>> I tried to edit the entry "*unit_system*" of the  file "
>>>>> *weewx-x.y.z/weewx.conf*" to 'metric', but when running the following 
>>>>> piece of code
>>>>>
>>>>> *for packet in vantage.genDavisArchiveRecords(since_ts):*
>>>>> * print(packet)*
>>>>>
>>>>> I still get all the measurements in US system.
>>>>>
>>>>> What I am missing?
>>>>>
>>>>> Thank you very much for your help, I appreciate it :)
>>>>> Saverio
>>>>>
>>>>> -- 
>>>>> You received this message because you are subscribed to the Google 
>>>>> Groups "weewx-user" group.
>>>>> To unsubscribe from this group and stop receiving emails from it, send 
>>>>> an email to [email protected].
>>>>> To view this discussion on the web visit 
>>>>> https://groups.google.com/d/msgid/weewx-user/9e5b1613-3b95-4696-aa40-f928d42d3c92n%40googlegroups.com
>>>>>  
>>>>> <https://groups.google.com/d/msgid/weewx-user/9e5b1613-3b95-4696-aa40-f928d42d3c92n%40googlegroups.com?utm_medium=email&utm_source=footer>
>>>>> .
>>>>>
>>>> -- 
>> You received this message because you are subscribed to the Google Groups 
>> "weewx-user" group.
>> To unsubscribe from this group and stop receiving emails from it, send an 
>> email to [email protected].
>>
> To view this discussion on the web visit 
>> https://groups.google.com/d/msgid/weewx-user/321e3695-adfc-4b73-8d33-5fbbb2a2bab0n%40googlegroups.com
>>  
>> <https://groups.google.com/d/msgid/weewx-user/321e3695-adfc-4b73-8d33-5fbbb2a2bab0n%40googlegroups.com?utm_medium=email&utm_source=footer>
>> .
>>
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/3284c802-db98-49ee-b631-11bf0988a040n%40googlegroups.com.

Reply via email to