I have found the error:
there was software defined and so it doesn't work, once hardware is defined
it's OK.
correct
[StdArchive]
record_generation = hardware
gjr80 schrieb am Mittwoch, 15. März 2023 um 21:12:39 UTC+1:
> I suggest the first step is to run WeeWX directly
> <http://weewx.com/docs/usersguide.htm#Running_directly> to see exactly
> what is being included in the archive records. When run directly WeeWX will
> display loop packets (LOOP:) and archive records (REC:) to the console.
> rxCheckPrecent will (should) appear in archive records only. Let WeeWX
> run for at least a couple of archive periods to ensure you see at least one
> archive record and then post the entire console output here.
>
> Gary
> On Thursday, 16 March 2023 at 02:14:33 UTC+10 [email protected] wrote:
>
>> no rxCheckPercent data is read and written to the database. But on the
>> Davis Console the diagnostic screen shows a quality of 100%?
>> Where do I have to look further?
>> Any hints would be most welcome!
>> Geni
>
>
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion on the web visit
https://groups.google.com/d/msgid/weewx-user/4451b9d8-b79c-4a71-a3c8-799f3c30da2en%40googlegroups.com.