That’s great! Thanks for letting us know. rich On Friday 2 February 2024 at 18:29:13 UTC-5 Frank Gruhlke wrote:
> Tried option #2 and weewx is now reporting the barometer in inHg! Truely > appreciate your willingness to help! > > Thank you, thank you, thank you! > > On Friday, February 2, 2024 at 3:20:05 PM UTC-6 bell...@gmail.com wrote: > >> So it looks like your pressure is off by a factor of 100. I would think >> either of these would work (untested). >> >> http://www.weewx.com/docs/5.0/reference/weewx-options/stdcalibrate/?h=stdco >> [StdCalibrate] >> [[Corrections]] >> barometer = barometer / 100 >> >> >> https://github.com/bellrichm/WeeWX-MQTTSubscribe/wiki/Additional-Options#conversion_func >> >> >> [[[pa]]]] >> ignore = false # opt back in for this field >> name = barometer >> units = hPa >> >> conversion_func = lambda x : x / 100 >> >> I can see pros and cons of either. >> >> On Friday 2 February 2024 at 08:32:34 UTC-5 Frank Gruhlke wrote: >> >>> On a weewx re-boot this morning I spotted this warning: >>> >>> *WARNING weewx.qc: 2024-02-01 19:29:32 CST (1706837372) LOOP value >>> 'barometer' 2924.9393558775 <(939)%20355-8775> outside limits (26.0, 32.5)* >>> >>> Seems the driver is now converting the BME280 T reading of 98790.06 to >>> 2924.9393558775 <(939)%20355-8775>. Point of reference (30.00 in) is >>> about right for my location at this time. >>> Is there a way for the driver to also reformat the 2924.9393558775 >>> <(939)%20355-8775> to something more like 29.24 ? >>> >>> On Thursday, February 1, 2024 at 4:49:30 PM UTC-6 Frank Gruhlke wrote: >>> >>>> Hey Rich, thanks again... I managed to get my out-door temp to read F >>>> with this in my weewx.conf: >>>> >>>> [[[[temperature_C]]]] >>>> ignore = false >>>> name = outTemp >>>> units = degree_C >>>> >>>> I have tried every "units" option for Weewx Barometer unit ( inHg, >>>> mbar, hPa and kpa) >>>> for the "pa" field in my mqtt topic. >>>> >>>> [[[pa]]]] >>>> ignore = false # opt back in for this field >>>> name = barometer >>>> units = hPa >>>> >>>> I just get N/A (N/A) for the Barometer Reading in my reports. >>>> I don't see any errors restarting weewx. >>>> >>>> Here is what I am subscribed to in the driver. >>>> "pa" is the pressure reading I am trying to bring into Weewx >>>> >>>> { >>>> "tempc": 20.59, >>>> "tempf": 69.062, >>>> "hum": 38.88184, >>>> "pa": 98790.06, >>>> "altim": 213.1839, >>>> "altift": 699.4224 >>>> } >>>> >>>> >>>> *Any Ideas?* >>>> >>>> >>>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/88fd1258-aa81-4dcb-9d7c-e7280805363bn%40googlegroups.com.