If all you are looking for is pressure and inside temp, depending on your 
setup, you could add a BME280 sensor (pressure, temp, and humidity). It 
used these 
instructions: https://github.com/bdwilson/acurite/blob/master/Pressure.md

And then add the bme280 weewx extension. Then you can run SDR as your 
driver and the bme280 data will be added as a service call.

On Tuesday, March 12, 2024 at 4:14:53 AM UTC-4 Greg from Oz wrote:

> I have a question:
> What happens if I get the same records from the SDR and the USB?
> Is there a way to filter out the USB fineoffset data fields I don't need 
> because they will be coming from the SDR?
> I only need inside temperature and pressure from the USB.
> I tried to comment out all the fields I didn't need in the fine offset 
> driver but that failed.
> /opt/weewx/weewx-venv/lib/python3.11/site-packages/weewx/drivers/fousb.py
>
> Back to the drawing board.
>
>
> On Tuesday 12 March 2024 at 12:51:38 UTC+11 Greg from Oz wrote:
>
>> Yeah I think I will do the same . I was leaning that way because 
>> everything else looked too hard.
>> I have MQTT already set up.
>> Thanks
>>
>> On Tuesday 12 March 2024 at 10:44:15 UTC+11 [email protected] wrote:
>>
>>> My solution was to run rtl_433 as a separate service that publishes to 
>>> MQTT. I then run MQTTSubscribe to augment the station/driver data. I 
>>> already had the MQTT infrastructure, so it was a minor lift for me.
>>> Some more information is here, 
>>> https://groups.google.com/g/weewx-user/c/svsbOxWvPZc/m/eLA6lhyJAAAJ.
>>> rich
>>>
>>> On Monday 11 March 2024 at 01:49:59 UTC-4 Greg from Oz wrote:
>>>
>>>> Hi,
>>>> I have spent hours trying to figure out how to have 2 hardware sources 
>>>> (sdr and fineoffset USB console) and get most data from the sdr and just 
>>>> the barometer and inside temperature from the fine offset USB console.
>>>>
>>>> I just want all the data from both devices to go into the one database.
>>>>
>>>> Is this even possible?
>>>>
>>>> I have found examples of 2 hardware devices and 2 databases but I don't 
>>>> want that.
>>>>
>>>> The reason I want to do this is because the console is showing a lot of 
>>>> :
>>>> ERROR weewx.drivers.fousb: get_observations failed: [Errno 19] No such 
>>>> device (it may have been disconnected)
>>>>
>>>> The only way to fix those errors is to turn the console on and off 
>>>> which I have automated but it is doing it a lot lately and and it is even 
>>>> showing up on my graphs.
>>>>
>>>> If I can't get the barometer and inside temperature I won't be 
>>>> heartbroken but it would be nice to be able to do that.
>>>>
>>>> If I can get it to work I can just reset the console when it stops 
>>>> working and not have the barometer and inside temp but I should be able to 
>>>> at least get the majority of the data.
>>>>
>>>> Is there any documentation with examples anywhere? I did find something 
>>>> about creating a service but that looked way to complicated for my 
>>>> paygrade.
>>>>
>>>> Thanks
>>>>
>>>>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/cfc5cd8a-a23d-4ecd-a879-bb941cd476ben%40googlegroups.com.

Reply via email to