If all you are looking for is pressure and inside temp, depending on your setup, you could add a BME280 sensor (pressure, temp, and humidity). It used these instructions: https://github.com/bdwilson/acurite/blob/master/Pressure.md
And then add the bme280 weewx extension. Then you can run SDR as your driver and the bme280 data will be added as a service call. On Tuesday, March 12, 2024 at 4:14:53 AM UTC-4 Greg from Oz wrote: > I have a question: > What happens if I get the same records from the SDR and the USB? > Is there a way to filter out the USB fineoffset data fields I don't need > because they will be coming from the SDR? > I only need inside temperature and pressure from the USB. > I tried to comment out all the fields I didn't need in the fine offset > driver but that failed. > /opt/weewx/weewx-venv/lib/python3.11/site-packages/weewx/drivers/fousb.py > > Back to the drawing board. > > > On Tuesday 12 March 2024 at 12:51:38 UTC+11 Greg from Oz wrote: > >> Yeah I think I will do the same . I was leaning that way because >> everything else looked too hard. >> I have MQTT already set up. >> Thanks >> >> On Tuesday 12 March 2024 at 10:44:15 UTC+11 [email protected] wrote: >> >>> My solution was to run rtl_433 as a separate service that publishes to >>> MQTT. I then run MQTTSubscribe to augment the station/driver data. I >>> already had the MQTT infrastructure, so it was a minor lift for me. >>> Some more information is here, >>> https://groups.google.com/g/weewx-user/c/svsbOxWvPZc/m/eLA6lhyJAAAJ. >>> rich >>> >>> On Monday 11 March 2024 at 01:49:59 UTC-4 Greg from Oz wrote: >>> >>>> Hi, >>>> I have spent hours trying to figure out how to have 2 hardware sources >>>> (sdr and fineoffset USB console) and get most data from the sdr and just >>>> the barometer and inside temperature from the fine offset USB console. >>>> >>>> I just want all the data from both devices to go into the one database. >>>> >>>> Is this even possible? >>>> >>>> I have found examples of 2 hardware devices and 2 databases but I don't >>>> want that. >>>> >>>> The reason I want to do this is because the console is showing a lot of >>>> : >>>> ERROR weewx.drivers.fousb: get_observations failed: [Errno 19] No such >>>> device (it may have been disconnected) >>>> >>>> The only way to fix those errors is to turn the console on and off >>>> which I have automated but it is doing it a lot lately and and it is even >>>> showing up on my graphs. >>>> >>>> If I can't get the barometer and inside temperature I won't be >>>> heartbroken but it would be nice to be able to do that. >>>> >>>> If I can get it to work I can just reset the console when it stops >>>> working and not have the barometer and inside temp but I should be able to >>>> at least get the majority of the data. >>>> >>>> Is there any documentation with examples anywhere? I did find something >>>> about creating a service but that looked way to complicated for my >>>> paygrade. >>>> >>>> Thanks >>>> >>>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/cfc5cd8a-a23d-4ecd-a879-bb941cd476ben%40googlegroups.com.