i have same situation - archive interval 5m, lorawan sensors 20m - so my 5 min 
reports aggregate the lorawan sensors over last 20m to pick up the last value 
each time e.g.
[[[plots/dayrivercomb]]]
    aggregate_type = last
    aggregate_interval = 1200  # 20 mins
    line_gap_fraction = 0.05
    [[[[river_level]]]]
    [[[[river_level2]]]]
    [[[[river_level4]]]]
        color = black
cheers
⊣GE⊢

> On 25 Jul 2024, at 1:12 AM, [email protected] <[email protected]> wrote:
> 
> My problem is definitely caused by the archive period (15 minutes) and the 
> sensor reporting time (20 minutes)

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/86BA36ED-CF5B-494B-BDA4-039B39CD3D18%40geddy.au.

Reply via email to