I am not allowed to change the archive interval inside the console. It is 
safer to preserve data this way: weatherlink devices store 7200 packets, so 
one hour interval gives around 10 months storing memory.

On Wednesday, 5 November 2025 at 11:51:58 UTC-3 Tom Keffer wrote:

> I'm not following. Why not just change the archive interval 
> <https://www.weewx.com/docs/5.2/hardware/vantage/#vantage_archive_interval> 
> to something smaller?
>
>
>
> On Wed, Nov 5, 2025 at 6:11 AM tomas <[email protected]> wrote:
>
>> Hello, I have an instance of weewx attached to a weatherlink device, as 
>> usual. Archive_interval is set to one hour in the console. 
>>
>> If I choose *record_generation = hardware*
>> I get sticked to one hour interval.
>>
>> And if I choose   *record_generation = software,*
>> I cannot catch up with the console's database after a powerdown.
>>
>>
>> Is there a way to increase frequency in my weewx database (and restful 
>> posts) and still catching up console's database when starting weewx?
>>
>>
>>
>> -- 
>> You received this message because you are subscribed to the Google Groups 
>> "weewx-user" group.
>> To unsubscribe from this group and stop receiving emails from it, send an 
>> email to [email protected].
>> To view this discussion visit 
>> https://groups.google.com/d/msgid/weewx-user/4d9d3ec5-0683-4b45-ab0d-166f00edcaefn%40googlegroups.com
>>  
>> <https://groups.google.com/d/msgid/weewx-user/4d9d3ec5-0683-4b45-ab0d-166f00edcaefn%40googlegroups.com?utm_medium=email&utm_source=footer>
>> .
>>
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion visit 
https://groups.google.com/d/msgid/weewx-user/61bda418-b823-46b1-92d5-2c045412109fn%40googlegroups.com.

Reply via email to